Gong J, Högman C F, Lundholm M, Gustafsson I
Department of Clinical Immunology and Transfusion Medicine, University Hospital, Uppsala, Sweden.
APMIS. 1994 Jan;102(1):72-8. doi: 10.1111/j.1699-0463.1994.tb04848.x.
The recovery of bacteria and the speed of detection of microbial growth in platelet concentrates (PC) were studied, comparing a novel automated blood culture system (BacT/Alert) with two traditional methods. Full-scale experiments were performed with a total of 33 units of PC (average content 320 x 10(9) platelets per unit) obtained from pooled buffy coats. Six strains known as possible PC contaminants were tested: S. epidermidis, S. aureus, P. aeruginosa, B. cereus, E. aerogenes, and S. sanguis. Using an inoculum of 50-98 bacteria/ml, bacterial contamination was detected in all of 11 PCs on 132 sampling occasions. With a small inoculum (0.3-9 bacteria/ml), the bacterial contamination was detected in all PCs in which abundant growth appeared, but failed to be detected in some instances where the bacterial content was very small. All of 11 uninoculated PC controls were negative. With the automated method the time for detection of a culture-positive PC was 6-16 h, clearly shorter than with the two manual-visual systems. The new system provides a rapid, reliable, and labour-saving method for screening of bacterial contamination in PCs. This would increase safety particularly if the present 5-day shelf life were extended.
研究了血小板浓缩物(PC)中细菌的回收率和微生物生长的检测速度,将一种新型自动血培养系统(BacT/Alert)与两种传统方法进行了比较。使用从混合白膜中获得的总共33单位PC(每单位平均含320×10⁹个血小板)进行了全面实验。测试了六种已知可能污染PC的菌株:表皮葡萄球菌、金黄色葡萄球菌、铜绿假单胞菌、蜡样芽孢杆菌、产气肠杆菌和血链球菌。使用50 - 98个细菌/毫升的接种量,在132次采样中,11份PC中的所有样本均检测到细菌污染。接种量较小时(0.3 - 9个细菌/毫升),在所有出现大量生长的PC中均检测到细菌污染,但在某些细菌含量非常少的情况下未能检测到。11份未接种的PC对照均为阴性。采用自动方法检测培养阳性PC的时间为6 - 16小时,明显短于两种手动视觉系统。新系统为筛查PC中的细菌污染提供了一种快速、可靠且省力的方法。如果将目前5天的保质期延长,这将提高安全性。