Suppr超能文献

Comparison of measured and computed epicardial potentials from a patient-specific inverse model.

作者信息

Budgett D M, Monro D M, Edwards S W, Stanbridge R D

机构信息

Department of Electrical Engineering, Imperial College of Science, Technology and Medicine, London, England.

出版信息

J Electrocardiol. 1993;26 Suppl:165-73.

PMID:8189121
Abstract

This study reports the first direct comparison of measured and computed epicardial potentials in which the specific anatomy of a test subject has been used to calculate the inverse electrocardiographic model. It is now feasible to obtain low-noise body surface potential maps and to incorporate accurate anatomic data into inverse procedures for the purpose of computing epicardial potential distributions. The direct verification of computed human epicardial distributions remains an important goal. The experiment reported here obtained direct measurements from six transcutaneous pacing wires that were attached to points on the epicardial surface of the human heart in an intact subject. From the same subject, a magnetic resonance scan was used to produce a specific thoracic model consisting of 5-mm cubes. The forward model uses the finite difference method to compute a forward transfer matrix that relates each of 26 epicardial regions to body surface measurements. The inverse computation was performed by zero-order Tikhonov regularization. Body surface potentials were used in the inverse procedure to compute epicardial potentials, which were then compared with direct epicardial measurements. The computed epicardial potentials were compared to the measured ones by correlation, which gave an amplitude-independent measure of similarity. Amplitude differences and time delays in computed potentials were observed, but the morphologic trend was generally well recovered. The results obtained indicate the sensitivity of the inverse model to a number of factors. The robustness of computed epicardial distributions to errors in assumed lung conductivity is shown. Results from a nonpatient-specific, but realistic, torso model are presented.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验