A motor-driven ventricular assist device controlled with an optical encoder system.

作者信息

Nakamura T, Hayashi K, Yamane H

机构信息

Department of Electrical and Information Engineering, Faculty of Engineering, Yamagata University, Yonezawa, Japan.

出版信息

Biomed Mater Eng. 1993 Fall;3(3):153-65.

PMID:8193567
Abstract

An electric motor-driven ventricular assist device has been developed for long-term use inside the body. The system is composed of a pusher-plate-type blood pump and an actuator consisting of an electrical motor and a ball screw. Cyclic change of the direction of motor rotation makes a back-and-forth axial movement of the ball screw shaft. The shaft, which is detached from the pump diaphragm, pushes the diaphragm via a pusher plate to eject blood during systole; blood is sucked by the diaphragm resilience during diastole. Using the output signals from a newly designed, incremental-type, miniature optical rotary encoder mounted inside the actuator, the input voltage of the motor is optimally controlled referring to the phase difference between the current position of the moving rotor and the electrical reference signal of the rotation generated by a microprocessor-based controller. In vitro performance tests indicated that the system fulfills required specifications. The maximum efficiency was 11%, which was about twice as high as that obtained with the previous open-loop prototype system. In the air, the surface temperature of the actuator elevated to 20 degrees C above the room temperature. An acute in vivo test showed its feasibility as a left ventricular assist device. Analysis of the energy loss in each component of the system indicated that redesign and precise assembly of the mechanical parts could increase the system efficiency.

摘要

相似文献

1
A motor-driven ventricular assist device controlled with an optical encoder system.
Biomed Mater Eng. 1993 Fall;3(3):153-65.
2
Determinant factors of efficiency of a motor-driven ventricular assist device.电动心室辅助装置效率的决定因素。
Biomed Mater Eng. 1994;4(1):27-36.
3
Control of a rotary pulsatile cardiac assist pump driven by an electric motor without a pressure sensor to avoid collapse of the pump inlet.
ASAIO J. 1993 Jul-Sep;39(3):M237-41.
4
Assessment and improvement of the system efficiency for the moving-actuator type biventricular assist device.移动驱动型双心室辅助装置系统效率的评估与改进
Artif Organs. 2004 Jun;28(6):549-55. doi: 10.1111/j.1525-1594.2004.07266.x.
5
A completely implanted left ventricular assist device. Chronic in vivo testing.
ASAIO J. 1993 Jul-Sep;39(3):M427-32.
6
An optimal controller for an electric ventricular-assist device: theory, implementation, and testing.一种用于电动心室辅助装置的最优控制器:理论、实现与测试。
IEEE Trans Biomed Eng. 1992 Apr;39(4):394-403. doi: 10.1109/10.126612.
7
Development of a prototype magnetically suspended rotor ventricular assist device.磁悬浮转子心室辅助装置原型的研制
ASAIO J. 1996 Jul-Aug;42(4):275-81.
8
Development of an implantable motor-driven assist pump system.可植入式电动辅助泵系统的研发
IEEE Trans Biomed Eng. 1990 Feb;37(2):146-56. doi: 10.1109/10.46254.
9
Development of the pulsation device for rotary blood pumps.
Artif Organs. 2005 Nov;29(11):912-5. doi: 10.1111/j.1525-1594.2005.00159.x.
10
Design of a miniature implantable left ventricular assist device using CAD/CAM technology.
J Artif Organs. 2003;6(3):162-7. doi: 10.1007/s10047-003-0223-y.

引用本文的文献

1
Position Sensors for Industrial Applications Based on Electromagnetic Encoders.基于电磁编码器的工业应用位置传感器。
Sensors (Basel). 2021 Apr 13;21(8):2738. doi: 10.3390/s21082738.