Bio Image Visage 2000与GELLAB-II二维电泳图像分析系统的比较。

Comparison of the Bio Image Visage 2000 and the GELLAB-II two-dimensional electrophoresis image analysis systems.

作者信息

Myrick J E, Lemkin P F, Robinson M K, Upton K M

机构信息

Division of Environmental Health Laboratory Sciences, Centers for Disease Control and Prevention (CDC), Atlanta, GA 30341-3724.

出版信息

Appl Theor Electrophor. 1993;3(6):335-46.

PMID:8199227
Abstract

To compare the Visage 2000 analysis system (Bio Image, Ann Arbor, MI, USA) with the GELLAB-II analysis system (National Cancer Institute, Frederick, MD, USA), we used each to perform image analysis of the same 29 silver-stained two-dimensional electrophoresis (2DE) gel image files from a study of urinary proteins in metal recovery plant workers who had confirmed body burdens of cadmium. Visage, aided by interactive analysis, detected an average of 890 +/- 177.6 spots per gel, or a total of 25,800 spots, whereas GELLAB-II detected 1971 +/- 198.5 spots per gel, or a total of 57,160 (a 222% increase over the Visage system), without operator intervention. Visage automatically quantified 52.5% (13,556) of the spots; 47.2% (12,173), consisting mostly of larger spots, had to be quantified interactively with an image editor, and 0.3% (71) were not quantified. GELLAB-II automatically quantified all detected spots. After we interactively assigned the maximum allowed number of landmarks (30 for Visage and 52 for GELLAB-II), we found that Visage matched 657 +/- 211.2 spots per gel, and GELLAB-II matched all detected spots and also extrapolated an average of 1269 virtual spots per gel. Plots of densities from the two systems on selected spots showed excellent agreement, and both systems showed high correlation between their measurements of the beta-2-microglobulin spot densities and an independent radioimmunoassay quantification of the original urine samples. By comparing the regression of the densities of all spots with urinary cadmium (UCD) levels, we found that several of the same detected spots from each system were highly correlated. The densities of four acidic proteins with relative molecular weights of approximately 112,000 Da (as quantified by GELLAB-II but not by Visage) were highly correlated with UCD concentrations. These proteins are new candidate biomarkers of cadmium toxicity. We compared the estimated labor costs of using each system to analyse a hypothetical 20-sample (60 gels) 2DE study and found that GELLAB-II was six times less expensive to use than Visage, primarily because of the operator time required to do interactive error correction with the Visage system.

摘要

为了比较Visage 2000分析系统(美国密歇根州安阿伯市Bio Image公司)和GELLAB-II分析系统(美国马里兰州弗雷德里克市国家癌症研究所),我们使用这两种系统对来自一项针对已确认镉体内负荷的金属回收厂工人尿液蛋白质研究的29个银染二维电泳(2DE)凝胶图像文件进行图像分析。在交互式分析的辅助下,Visage系统平均每张凝胶检测到890±177.6个斑点,总计25800个斑点;而GELLAB-II系统在无需操作人员干预的情况下,每张凝胶检测到1971±198.5个斑点,总计57160个斑点(比Visage系统增加了222%)。Visage系统自动定量了52.5%(13556个)的斑点;47.2%(12173个,主要是较大的斑点)必须使用图像编辑器进行交互式定量,0.3%(71个)未进行定量。GELLAB-II系统自动定量了所有检测到的斑点。在我们交互式地指定了最大允许地标数量(Visage为30个,GELLAB-II为52个)之后,我们发现Visage系统每张凝胶匹配657±211.2个斑点,而GELLAB-II系统匹配了所有检测到的斑点,并且每张凝胶还平均外推了1269个虚拟斑点。对选定斑点上两个系统的密度图进行比较,结果显示一致性极佳,并且两个系统在β-2-微球蛋白斑点密度测量值与原始尿液样本的独立放射免疫分析定量之间均显示出高度相关性。通过比较所有斑点密度与尿镉(UCD)水平的回归分析,我们发现每个系统检测到的几个相同斑点具有高度相关性。四种相对分子质量约为112000 Da的酸性蛋白质的密度(GELLAB-II系统能够定量,而Visage系统不能)与UCD浓度高度相关。这些蛋白质是镉毒性的新候选生物标志物。我们比较了使用每个系统分析一项假设的20个样本(60张凝胶)的2DE研究的估计劳动力成本,发现使用GELLAB-II系统的成本比Visage系统低六倍,主要原因是使用Visage系统进行交互式误差校正需要操作人员花费时间。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验