Aoyagi M, Furuse H, Yokota M, Kiren T, Suzuki Y, Koike Y
Department of Otolaryngology, Yamagata University School of Medicine, Japan.
Acta Otolaryngol Suppl. 1994;511:23-7. doi: 10.3109/00016489409128296.
To assess the detectability of amplitude-modulation following response (AMFR) elicited at different carrier (CFs) and modulation frequencies (MFs) during sleep, as well as the usefulness of AMFR in evoked response audiometry, AMFR was examined in 10 adults with normal hearing while sleeping. The stimulus was a 50 dBnHL sinusoidally amplitude-modulated (SAM) tone with a modulation depth of 95%. The MF of the stimulus tone was varied from 20 to 120 Hz in 20 Hz steps and CFs were 500, 1000, 2000 and 4000 Hz. An SAM tone with a CF of 20,000 Hz was used for stimulation in 5 subjects to confirm that the response did not contain any artifact. Response was determined by phase spectral analysis. The component synchrony measure of AMFRs at MF of 40 Hz (40-Hz AMFR) was high at lower CFs, but 40-Hz AMFRs at higher CFs were unreliable. The detectability of 80-Hz AMFR was high for all CFs. It was confirmed that the response waveform was not contaminated by any electromagnetic artifact. Eighty-Hz AMFR detected by phase spectral analysis should thus be useful for predicting frequency-specific hearing thresholds during sleep.
为评估睡眠期间在不同载波频率(CFs)和调制频率(MFs)下诱发的调幅跟随反应(AMFR)的可检测性,以及AMFR在诱发反应测听中的效用,对10名听力正常的成年人在睡眠状态下进行了AMFR检测。刺激声为50 dBnHL的正弦调幅(SAM)音,调制深度为95%。刺激音的MF以20 Hz步长从20变化到120 Hz,CFs分别为500、1000、2000和4000 Hz。对5名受试者使用CF为20,000 Hz的SAM音进行刺激,以确认反应中不包含任何伪迹。通过相位谱分析确定反应。在较低CFs时,40 Hz调制频率下的AMFR(40-Hz AMFR)的成分同步测量值较高,但在较高CFs时,40-Hz AMFR不可靠。对于所有CFs,80-Hz AMFR的可检测性都很高。已确认反应波形未被任何电磁伪迹污染。因此,通过相位谱分析检测到的80-Hz AMFR应有助于预测睡眠期间特定频率的听力阈值。