Suppr超能文献

在0.064T质子磁共振相位成像中硅胶与水和脂肪的鉴别

Differentiation of silicone gel from water and fat in MR phase imaging of protons at 0.064 T.

作者信息

Derby K A, Frankel S D, Kaufman L, Carlson J W, Mineyev M I, Occhipinti K A, Friedenthal R

机构信息

Toshiba America MRI, South San Francisco, Calif.

出版信息

Radiology. 1993 Nov;189(2):617-20. doi: 10.1148/radiology.189.2.8210399.

Abstract

The authors present a method of identifying silicone at magnetic resonance (MR) imaging based on its chemical shift. The method relies on phase images reconstructed from a gradient-recalled-echo sequence that has an echo time chosen to maximize the phase offsets between water, fat, and silicone. Results from studies at 0.064 T of both phantoms and human subjects are presented. This technique was useful in identifying extracapsular silicone and may be applicable at other field strengths.