Suppr超能文献

脐血穿刺术对脐动脉和大脑中动脉血流速度波形的影响。

The effect of cordocentesis on umbilical and middle cerebral artery blood flow velocity waveforms.

作者信息

Hecher K, Stettner H, Spernol R, Harrington K, Szalay S

机构信息

Department of Obstetrics and Gynaecology, Klagenfurt Hospital, Austria.

出版信息

Br J Obstet Gynaecol. 1993 Sep;100(9):828-31. doi: 10.1111/j.1471-0528.1993.tb14308.x.

Abstract

OBJECTIVE

To investigate the effect of cordocentesis on the umbilical and fetal cerebral circulation.

DESIGN

Cross sectional study.

SETTING

Department of Obstetrics and Gynaecology, Regional Referral Centre for Fetal Medicine, Klagenfurt Hospital, Austria.

SUBJECTS

Thirty pregnant women undergoing diagnostic cordocentesis at 18 to 38 weeks' gestation.

INTERVENTIONS

The pulsatility index (PI) in the umbilical artery and fetal middle cerebral artery was measured by pulsed Doppler ultrasound before and immediately after cordocentesis.

MAIN OUTCOME MEASURES

Change in umbilical artery PI and middle cerebral artery PI.

RESULTS

Cordocentesis was associated with a significant decrease in both umbilical artery PI (median -0.18, range -2.21 to 1.5, P < 0.004) and middle cerebral artery PI (mean -0.15, SD 0.32, P < 0.03) and the decrease in umbilical artery PI was most marked when cordocentesis was performed transplacentally. In four cases, there were absent or reversed frequencies at the end of diastole (EDF) in the umbilical artery before cordocentesis, and in all cases there were positive EDF after the procedure. In contrast, one of the 26 cases with positive EDF developed reversed EDF following the procedure.

CONCLUSIONS

Acute alterations in the waveforms from both the umbilical and fetal cerebral circulation can be induced by cordocentesis. The decrease in resistance in the fetoplacental circulation could be attributed to the release of vasodilators, and the increase in resistance observed in some cases could be secondary to arterial vasospasm. Better understanding of the underlying mechanisms might help in making cordocentesis a safer procedure.

摘要

目的

探讨脐血穿刺术对脐循环及胎儿脑循环的影响。

设计

横断面研究。

地点

奥地利克拉根福医院胎儿医学区域转诊中心妇产科。

研究对象

30例孕18至38周接受诊断性脐血穿刺术的孕妇。

干预措施

在脐血穿刺术前及穿刺后即刻,采用脉冲多普勒超声测量脐动脉和胎儿大脑中动脉的搏动指数(PI)。

主要观察指标

脐动脉PI和大脑中动脉PI的变化。

结果

脐血穿刺术与脐动脉PI(中位数-0.18,范围-2.21至1.5,P<0.004)和大脑中动脉PI(均值-0.15,标准差0.32,P<0.03)的显著降低相关,经胎盘进行脐血穿刺术时脐动脉PI的降低最为明显。4例在脐血穿刺术前脐动脉舒张末期出现无血流或反向血流,术后所有病例均出现正向舒张末期血流。相反,26例正向舒张末期血流的病例中有1例在术后出现反向舒张末期血流。

结论

脐血穿刺术可引起脐循环和胎儿脑循环波形的急性改变。胎儿胎盘循环阻力降低可能归因于血管舒张剂的释放,而某些病例中观察到的阻力增加可能继发于动脉血管痉挛。更好地理解潜在机制可能有助于使脐血穿刺术更安全。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验