McBride K D, Gaines P A, Beard J D
Department of Radiology, Royal Hallamshire Hospital, Sheffield, UK.
Eur J Radiol. 1993 Sep;17(2):101-5. doi: 10.1016/0720-048x(93)90043-m.
Initial experience with a new technique, using an inflatable compression device during ascending phlebography, is described. This method is compared with standard varicography in a small series of patients with recurrent varicose veins. In this pilot study, 13 patients had 17 limbs examined by the new method and 14 limbs by varicography. Below knee perforator incompetence was demonstrated directly in all limbs by 'pneumatic phlebography'. Short-saphenous vein and mid-thigh perforator incompetence were also more frequently demonstrated. The two tests are comparable at showing recurrent or persistent connection at the groin (13 limbs, overall). With modifications of the pressure device, pneumatic phlebography may prove to be an important method of assessing recurrent varicose veins.
本文描述了一种新技术的初步经验,即在上行静脉造影期间使用充气加压装置。该方法与标准静脉造影法在一小系列复发性静脉曲张患者中进行了比较。在这项初步研究中,13例患者的17条肢体接受了新方法检查,14条肢体接受了静脉造影检查。通过“气性静脉造影”在所有肢体中直接证实了膝下穿通支功能不全。小隐静脉和大腿中部穿通支功能不全也更频繁地得到证实。两种检查在显示腹股沟处复发性或持续性连接方面具有可比性(总共13条肢体)。通过对压力装置进行改进,气性静脉造影可能会成为评估复发性静脉曲张的一种重要方法。