Suppr超能文献

膝关节离断截肢者使用Multiflex足部与Quantum足部的步态比较。

Comparison of gait using a Multiflex foot versus a Quantum foot in knee disarticulation amputees.

作者信息

Boonstra A M, Fidler V, Spits G M, Tuil P, Hof A L

机构信息

Department of Rehabilitation Medicine, Groningen University Hospital, The Netherlands.

出版信息

Prosthet Orthot Int. 1993 Aug;17(2):90-4. doi: 10.3109/03093649309164362.

Abstract

The subjective responses and gait patterns of unilateral knee disarticulation amputees wearing prostheses fitted first with the Multiflex foot and then with the Quantum foot were studied. Nine amputees were included in the trial. A questionnaire asked the amputees about their preference for one of the feet. Gait analysis was performed measuring temporal parameters and goniometry of hips, knees and ankles in the sagittal and frontal planes. There was a slight preference for the Quantum foot. Preference seemed not to be related to physical characteristics of the amputees nor to gait parameters. There were no differences in gait as far as the temporal factors were concerned. The main differences in the range of motion of the joints were in the frontal plane: the eversion-inversion movement of the ankle and the adduction-abduction movement of the hip. During walking at comfortable speed with the Multiflex foot the ankle and hip range of motion averaged 2.1 and 3.1 degrees respectively, less than during walking with the Quantum foot.

摘要

研究了单侧膝关节离断截肢者佩戴假肢时的主观反应和步态模式,先佩戴配备Multiflex脚的假肢,然后佩戴配备Quantum脚的假肢。9名截肢者参与了该试验。通过问卷调查询问截肢者对其中一种脚的偏好。进行步态分析,测量矢状面和额状面的时间参数以及髋、膝和踝关节的角度。对Quantum脚有轻微偏好。偏好似乎与截肢者的身体特征或步态参数无关。就时间因素而言,步态没有差异。关节活动范围的主要差异在额状面:踝关节的外翻-内翻运动和髋关节的内收-外展运动。佩戴Multiflex脚以舒适速度行走时,踝关节和髋关节的活动范围平均分别为2.1度和3.1度,小于佩戴Quantum脚行走时的活动范围。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验