We describe the implementation of a simple data interface between a radiology information system and a computed radiography system that uses personal computers and standard software. The radiology information system was developed in house and runs in a local area network of personal computers. The computed radiography system is connected to a picture archiving and communication system. We have implemented a software data interface on a microcomputer, allowing automated transfer of patient data from the radiology information system program to the computed radiography scheduling program. The interface adds essential information used by the picture archiving and communication system to handle work lists, routing, and archiving algorithms. We have improved the user interface, shortened the scheduling time, enabled coherence of data bases, and eased the use of computed radiography and examination routing in the picture archiving and communication system. We have been using this interface for more than 1 year without difficulties. This custom solution addresses the problem of interconnecting existing equipment, avoiding proprietary restrictions or the lack of effective standards. This approach can be applied to any radiology environment that uses personal computers.
我们描述了一种在放射信息系统与计算机X线摄影系统之间实现的简单数据接口,该接口使用个人计算机和标准软件。放射信息系统是内部开发的,运行在个人计算机的局域网中。计算机X线摄影系统连接到图像存档与通信系统。我们在一台微型计算机上实现了一个软件数据接口,允许将患者数据从放射信息系统程序自动传输到计算机X线摄影调度程序。该接口添加了图像存档与通信系统用于处理工作列表、路由和存档算法的基本信息。我们改进了用户界面,缩短了调度时间,实现了数据库的一致性,并简化了图像存档与通信系统中计算机X线摄影和检查路由的使用。我们使用这个接口已经超过一年,没有遇到任何问题。这个定制解决方案解决了现有设备互连的问题,避免了专有限制或缺乏有效标准的情况。这种方法可以应用于任何使用个人计算机的放射环境。