科赫囊内打孔器。关于其连续96例使用情况的报告。

The Koch endocapsular punch. A report on its use in 96 consecutive cases.

作者信息

Versace P, Francis I C

机构信息

Sydney Eye Hospital, Wooloomooloo, New South Wales, Australia.

出版信息

Aust N Z J Ophthalmol. 1993 Aug;21(3):153-6.

PMID:8260152
Abstract

The technique of endocapsular cataract extraction and intraocular lens implantation surgery provides optimal surgical conditions and more reliable intraocular lens positioning in the capsular bag. Several capsulectomy techniques are in use to remove anterior capsule from the central zone. The Koch endocapsular punch provides a new technique for creating a continuous anterior capsulectomy. In this study the Koch punch was used in 96 eyes consecutively undergoing intended endocapsular cataract extraction and intraocular lens implantation. Ninety-five eyes had appropriate lens centration at six months. There were no cases of vitreous loss. Ninety-nine per cent of cases had visual acuity of 6/6 or better at six months. This data demonstrates the Koch endocapsular punch to be an effective and safe means for anterior capsulectomy.

摘要

囊内白内障摘除及人工晶状体植入手术技术可提供最佳手术条件,并使人工晶状体在囊袋内的定位更可靠。目前有多种撕囊技术用于从中央区移除前囊。科赫囊内打孔器提供了一种进行连续前囊撕囊的新技术。在本研究中,科赫打孔器被连续用于96例拟行囊内白内障摘除及人工晶状体植入的患者眼中。95只眼在6个月时人工晶状体居中良好。无玻璃体丢失病例。99%的病例在6个月时视力达到6/6或更好。这些数据表明,科赫囊内打孔器是一种有效且安全的前囊撕囊方法。