• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Platelet concentrates stored for 5 days in a reduced volume of plasma maintain hemostatic function and viability.

作者信息

Ali A M, Warkentin T E, Bardossy L, Goldsmith C H, Blajchman M A

机构信息

Canadian Red Cross Society, Hamilton, Ontario.

出版信息

Transfusion. 1994 Jan;34(1):44-7. doi: 10.1046/j.1537-2995.1994.34194098602.x.

DOI:10.1046/j.1537-2995.1994.34194098602.x
PMID:8273128
Abstract

BACKGROUND

Platelet concentrates prepared from whole blood are generally suspended in a standard volume of 50 to 60 mL of plasma and can be stored thus at 20 to 24 degrees C for up to 5 days. In vitro studies suggested that this plasma volume could be reduced to 30 to 35 mL without impairing platelet function.

STUDY DESIGN AND METHODS

This study evaluated whether platelets stored for 5 days in a reduced volume (30-35 mL) of plasma maintained their in vivo viability, hemostatic function, and recovery in recipients. Paired autologous platelet survival studies were done in 20 adult volunteers to assess platelet viability. A rabbit ear bleeding-time model was used to compare the hemostatic effectiveness of human platelet concentrates stored for 5 days in the standard or reduced volume of plasma. Platelet recovery was compared in thrombocytopenic hospital patients.

RESULTS

Paired platelet survival studies indicated no significant difference between the values in platelet concentrates stored for 5 days in the reduced volume of plasma and the values in those stored in the standard volume. In the animal model, there was no significant difference in the bleeding times achieved by either set of platelet concentrates. The platelet count increments in thrombocytopenic patients were measured. The platelet count increments in patients who received reduced-volume platelet concentrates were as good as the increments achieved in patients given standard-volume concentrates.

CONCLUSION

The in vivo viability, recovery, and hemostatic function of platelets collected in polyvinylchloride plastic containers and stored in 30 to 35 mL of plasma for 5 days are maintained as well as those of platelets stored in 50 to 60 mL of plasma.

摘要

相似文献

1
Platelet concentrates stored for 5 days in a reduced volume of plasma maintain hemostatic function and viability.
Transfusion. 1994 Jan;34(1):44-7. doi: 10.1046/j.1537-2995.1994.34194098602.x.
2
Extension of platelet concentrate storage.
Transfusion. 1983 May-Jun;23(3):207-12. doi: 10.1046/j.1537-2995.1983.23383224896.x.
3
Evaluation of platelet concentrates stored for 5 days with reduced plasma volume.对血浆体积减少储存5天的血小板浓缩物的评估。
Transfusion. 1994 Jan;34(1):39-43. doi: 10.1046/j.1537-2995.1994.34194098601.x.
4
Recovery, lifespan, and function of CPD-Adenine (CPDA-1) platelet concentrates stored for up to 72 hours at 4 C.在4℃下储存长达72小时的CPD-腺嘌呤(CPDA-1)血小板浓缩物的恢复、寿命和功能。
Transfusion. 1980 Sep-Oct;20(5):498-503. doi: 10.1046/j.1537-2995.1980.20581034501.x.
5
Reduction of the volume of stored platelet concentrates for use in neonatal patients.
Transfusion. 1984 Mar-Apr;24(2):144-6. doi: 10.1046/j.1537-2995.1984.24284173346.x.
6
Five-day storage of platelet concentrates.血小板浓缩物的五日储存。
Transfusion. 1984 Mar-Apr;24(2):147-52. doi: 10.1046/j.1537-2995.1984.24284173347.x.
7
Viability and function of platelet concentrates stored in CPD-adenine (CPDA-1).储存在枸橼酸盐-磷酸盐-葡萄糖-腺嘌呤(CPDA-1)中的血小板浓缩物的活力和功能。
Transfusion. 1980 Sep-Oct;20(5):489-97. doi: 10.1046/j.1537-2995.1980.20581034500.x.
8
Viability of platelets following storage in the irradiated state. A pair-controlled study.
Transfusion. 1988 Sep-Oct;28(5):446-50. doi: 10.1046/j.1537-2995.1988.28588337334.x.
9
Refined methods to evaluate the in vivo hemostatic function and viability of transfused human platelets in rabbit models.在兔模型中评估输注的人血小板体内止血功能和活力的改进方法。
Transfusion. 2017 Aug;57(8):2035-2044. doi: 10.1111/trf.14189. Epub 2017 Jul 5.
10
Determination viability of a transfused platelet product by corrected count increment and percentage platelet response.通过校正计数增加值和血小板反应百分比来确定输注血小板产品的活力。
Pan Afr Med J. 2017 Jul 28;27:226. doi: 10.11604/pamj.2017.27.226.12116. eCollection 2017.