Bochdansky T, Hertz H, Poigenfürst J
Universitätsklinik für Physikalische Medizin und Rehabilitation, Wien.
Unfallchirurgie. 1993 Oct;19(5):303-6. doi: 10.1007/BF02588126.
Twelve patients with dynamically treated ruptures of finger flexor tendons the median nerve was electroneurologically examined at an average of 16 months after operation. The parameters were abnormal in about one third to three quarters of the patients. In accordance with literature the reason for this is seen in pronounced flexion position of the wrist during treatment according to Kleinert.
12例手指屈肌腱动态治疗断裂患者,术后平均16个月对正中神经进行了神经电生理检查。约三分之一至四分之三的患者参数异常。与文献一致,其原因在于按照克莱纳特方法治疗期间手腕处于明显的屈曲位。