• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Computer simulation of broad-beam and narrow-beam attenuation in lead for diagnostic x-ray energies.

作者信息

McLean D

机构信息

University of Sydney, Faculty of Health Sciences, School of Medical Radiation Technology, Libcombe, NSW, Australia.

出版信息

Med Phys. 1993 Sep-Oct;20(5):1549-54. doi: 10.1118/1.597118.

DOI:10.1118/1.597118
PMID:8289739
Abstract

Significant differences between broad- and narrow-beam transmission measurements for lead protective barriers have been noted for x-ray beams in the diagnostic energy range. Work reported in this paper indicates that these differences in transmitted exposure between broad- and narrow-beam geometry measurements are primarily the result of two independent interaction processes; the transmission of K-characteristic photons produced in the barrier, and coherently scattered photons. The magnitude of these effects was studied for x-ray spectra between 70 and 150 kVp. The K-characteristic component was found to be maximal at 150 kVp, while the coherently scattered contribution was found to be maximal for thick barriers and at lower energies. The effect of beam field size on relative transmitted intensities was also studied and found to increase with increasing field size up to 30 cm. A detector-to-barrier distance of 10 cm was found to maximize the K-characteristic component. For a typical diagnostic x-ray potential of 100 kVp, the K-characteristic component was found to be less than 7% of the total transmitted beam. Voltage wave form considerations were found to be significant as has been previously reported. The contribution of K-characteristic photons has been mathematically modeled and a computer program written to allow the rapid computation of broad beam transmission exposures for lead barriers, once the appropriate beam specifications have been entered.

摘要

相似文献

1
Computer simulation of broad-beam and narrow-beam attenuation in lead for diagnostic x-ray energies.
Med Phys. 1993 Sep-Oct;20(5):1549-54. doi: 10.1118/1.597118.
2
Evaluation of the scattered radiations of lead and lead-free aprons in diagnostic radiology by MCNPX.利用MCNPX评估诊断放射学中铅质和无铅防护围裙的散射辐射。
Technol Health Care. 2017;25(3):513-520. doi: 10.3233/THC-161293.
3
Effects of scatter generated by beam-modifying absorbers in megavoltage photon beams.
Med Phys. 1995 Dec;22(12):2075-81. doi: 10.1118/1.597650.
4
Broad beam attenuation measurements in lead in kilovoltage X-ray beams.千伏级X射线束中铅的宽束衰减测量。
Z Med Phys. 2008;18(3):197-202. doi: 10.1016/j.zemedi.2008.04.008.
5
Application of the diagnostic radiological index of protection to protective garments.诊断放射防护指数在防护服中的应用。
Med Phys. 2015 Feb;42(2):653-662. doi: 10.1118/1.4905165.
6
Measured scattered x-ray energy spectra for simulated irradiation geometries in diagnostic radiology.诊断放射学中模拟照射几何条件下测量的散射X射线能谱。
Med Phys. 1996 Jul;23(7):1271-6. doi: 10.1118/1.597690.
7
Radiation shielding materials and radiation scatter effects for interventional radiology (IR) physicians.介入放射学医师用的辐射屏蔽材料和辐射散射效应。
Med Phys. 2012 Jul;39(7):4537-46. doi: 10.1118/1.4730504.
8
Analysis of spectral blur effects in x-ray scatter imaging.
Med Phys. 1999 Sep;26(9):1811-6. doi: 10.1118/1.598685.
9
Broad beam attenuation of kilovoltage photon beams: effect of ion chambers.千伏级光子束的宽束衰减:电离室的影响
Br J Radiol. 1998 Jan;71(841):68-73. doi: 10.1259/bjr.71.841.9534701.
10
Monte Carlo simulation of x-ray buildup factors of lead and its applications in shielding of diagnostic x-ray facilities.铅的X射线积累因子的蒙特卡罗模拟及其在诊断X射线设备屏蔽中的应用。
Med Phys. 2007 Apr;34(4):1398-404. doi: 10.1118/1.2710333.