Suppr超能文献

准分子激光冠状动脉成形术后冠状动脉穿孔:准分子激光冠状动脉成形术注册研究经验

Coronary perforation after excimer laser coronary angioplasty: the Excimer Laser Coronary Angioplasty Registry experience.

作者信息

Holmes D R, Reeder G S, Ghazzal Z M, Bresnahan J F, King S B, Leon M B, Litvack F

机构信息

Division of Cardiovascular Diseases and Internal Medicine, Mayo Clinic, Rochester, Minnesota 55905.

出版信息

J Am Coll Cardiol. 1994 Feb;23(2):330-5. doi: 10.1016/0735-1097(94)90415-4.

Abstract

OBJECTIVES

This study assessed the frequency of perforation with excimer coronary angioplasty.

BACKGROUND

Coronary artery perforation after conventional percutaneous transluminal coronary angioplasty is extremely rare. Because laser coronary angioplasty involves actual tissue ablation, it has an increased potential for perforation.

METHODS

All patients in the Excimer Laser Coronary Angioplasty Registry were included in this prospective study. Those who had a perforation related to the procedure were compared with those who did not have this complication.

RESULTS

Of 2,759 consecutive patients in the Excimer Laser Coronary Angioplasty Registry, 36 (1.3%) had perforation. In these patients, the left anterior descending coronary artery was the most frequently treated vessel (53%). There were no differences in fiber sizes between patients with and those without perforation. Among the patients with perforation, 36.1% required coronary artery bypass surgery, 16.7% experienced an infarction and 5.6% had a fatal outcome. Among the patients without perforation, the rates were 3.1%, 3.8% and 0.6%, respectively. However, 41.7% of the patients with documented coronary artery perforation did not need coronary artery bypass surgery or experience myocardial infarction or death. No angiographic characteristics distinguished lesions with from those without perforation. The frequency of coronary artery perforation declined over time with increasing operator experience, from 1.6% in the first 1,888 patients to only 0.4% in the last 1,000 patients (p = 0.002).

CONCLUSIONS

With increasing operator experience, the rate of perforation with excimer laser coronary angioplasty has decreased. When perforation occurs, subsequent event rates increase.

摘要

目的

本研究评估准分子激光冠状动脉成形术导致穿孔的发生率。

背景

传统经皮腔内冠状动脉成形术后冠状动脉穿孔极为罕见。由于激光冠状动脉成形术涉及实际的组织消融,其穿孔的可能性增加。

方法

准分子激光冠状动脉成形术登记处的所有患者均纳入本前瞻性研究。将发生与手术相关穿孔的患者与未发生该并发症的患者进行比较。

结果

准分子激光冠状动脉成形术登记处连续的2759例患者中,36例(1.3%)发生穿孔。在这些患者中,左前降支冠状动脉是最常接受治疗的血管(53%)。发生穿孔和未发生穿孔的患者之间光纤尺寸无差异。在发生穿孔的患者中,36.1%需要冠状动脉搭桥手术,16.7%发生心肌梗死,5.6%死亡。在未发生穿孔的患者中,这些比例分别为3.1%、3.8%和0.6%。然而,41.7%有冠状动脉穿孔记录的患者不需要冠状动脉搭桥手术,也未发生心肌梗死或死亡。没有血管造影特征能够区分发生穿孔和未发生穿孔的病变。随着术者经验的增加,冠状动脉穿孔的发生率随时间下降,从前1888例患者中的1.6%降至最后1000例患者中的仅0.4%(p = 0.002)。

结论

随着术者经验的增加,准分子激光冠状动脉成形术的穿孔率降低。穿孔发生时,后续事件发生率增加。