Kothapalli B
Department of Electrical Engineering, ADFA, University of New South Wales, ACT, Australia.
Med Biol Eng Comput. 1993 Sep;31(5):482-6. doi: 10.1007/BF02441983.
The recording of gastric electrical activity using cutaneous electrodes is known as electrogastrography, and the recorded electrogastrogram comprises the electrical control activity and the contraction-related electrical response activity. The electrogastrogram has been simulated using a three-dimensional model that takes the effect of inhomogeneities into consideration. The model reproduces the electrical control activity and the second component of the electrical response activity. Spike activity is not reproduced. The increase in amplitude towards the antrum and the phase coupling between various regions is reflected in the simulated electrogastrogram. There is a possibility of determining the velocity of propagation from the phase difference with electrodes located above the antrum.
使用皮肤电极记录胃电活动被称为胃电图描记法,记录的胃电图包括电控制活动和与收缩相关的电反应活动。胃电图已通过考虑不均匀性影响的三维模型进行模拟。该模型再现了电控制活动和电反应活动的第二成分。峰电位活动未被再现。模拟胃电图中反映出向胃窦方向的振幅增加以及各区域之间的相位耦合。根据与位于胃窦上方电极的相位差有可能确定传播速度。