Jose V J, Oommen R, Joseph G
Department of Cardiology, Christian Medical College Hospital, Vellore.
J Assoc Physicians India. 1993 May;41(5):272-4.
Fifty five consecutive patients diagnosed to have coronary artery disease by coronary angiography had their left ventricular (LV) diastolic functions evaluated by pulsed doppler (PD) methods and radionuclide angiography (RNA). Using PD, the peak velocities of the early filling wave 'E' and the late filling wave 'A' of mitral inflow were measured. LV diastolic dysfunction, defined as E/A ratio less than 1.0, was present in 31 of 38 patients with low RNA peak filling rates (PFR) of 2.3 EDV/sec or less (sensitivity 81.6%). Normal E/A ratios (> 1.0) were seen in 13 of 17 patients with normal RNA PFR of > 2.3 EDV/sec (specificity 76.5%). Both methods were in agreement in 44 of 55 patients (accuracy 80%). There was good direct correlation between RNA PFR and PD E/A ratio (correlation coefficient r = 0.51, P < 0.01). It is concluded that PD echocardiography is a simple and reliable method of identifying diastolic dysfunction in patients with ischaemic heart disease.
55例经冠状动脉造影确诊为冠心病的患者,采用脉冲多普勒(PD)法和放射性核素血管造影(RNA)对其左心室(LV)舒张功能进行评估。使用PD测量二尖瓣流入血流早期充盈波“E”和晚期充盈波“A”的峰值速度。LV舒张功能障碍定义为E/A比值小于1.0,在38例RNA峰值充盈率(PFR)为2.3 EDV/秒或更低的患者中有31例出现(敏感性81.6%)。17例RNA PFR大于2.3 EDV/秒的正常患者中有13例E/A比值正常(特异性76.5%)。两种方法在55例患者中的44例结果一致(准确性80%)。RNA PFR与PD E/A比值之间存在良好的直接相关性(相关系数r = 0.51,P < 0.01)。结论是,PD超声心动图是识别缺血性心脏病患者舒张功能障碍的一种简单可靠的方法。