Suppr超能文献

人类心肌交感神经支配的异质性:通过碘123标记的间碘苄胍闪烁显像在体内的证实。

Heterogeneity of the human myocardial sympathetic innervation: in vivo demonstration by iodine 123-labeled meta-iodobenzylguanidine scintigraphy.

作者信息

Gill J S, Hunter G J, Gane G, Camm A J

机构信息

Department of Cardiological Sciences, St. George's Hospital Medical School, Crammer Terrace, London, England.

出版信息

Am Heart J. 1993 Aug;126(2):390-8. doi: 10.1016/0002-8703(93)91056-k.

Abstract

The normal pattern of the myocardial sympathetic innervation was studied in 15 subjects using single photon emission computed tomography (SPECT) gamma scintigraphy with iodine 123-labeled meta-iodobenzylguanidine (I123MIBG). Seven young subjects (mean age 29.4 +/- 7.5 years SD) with supraventricular tachycardia and eight older patients (mean age 53.0 +/- 5.1 years SD) with normal coronary arteries at cardiac catheterization and normal thallium-201 scintigrams were studied. MIBG uptake in the hearts of six patients with complete cardiac denervation after orthotopic cardiac transplantation was also studied. MIBG scintigrams were reconstructed into bull's-eye target plots and divided into eight equal sectors. Within each sector, four areas representing the apical, two midventricular, and basal regions were defined. There was a reduction in counts in the older group of subjects with normal coronary anatomy (1218.2 +/- 198.4) as compared with younger subjects with supraventricular tachycardia (1124.4 +/- 317.6), (F = 15.0, df = 1, p < 0.001). The difference was lost after adjustment for age (p = 0.2) by means of analysis of covariance. There was a difference in counts within different sectors of the scan (F = 5.7, df = 7, p < 0.001), with lateral and anterior sectors having higher counts than septal and inferior sectors. There was no difference in the counts within areas of the scan (F = 0.04, df = 3, not significant [NS]) or different areas within the sectors (F = 1.1, df = 21, NS). A small diminution of counts (approximately 10%) in the 10 o'clock region of the bull's-eye target plot was observed in some scans.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

采用单光子发射计算机断层扫描(SPECT)γ闪烁显像技术,使用碘123标记的间碘苄胍(I123MIBG),对15名受试者的心肌交感神经支配正常模式进行了研究。研究对象包括7名患有室上性心动过速的年轻受试者(平均年龄29.4±7.5岁,标准差)以及8名年龄较大的患者(平均年龄53.0±5.1岁,标准差),后者在心脏导管检查中冠状动脉正常,铊201闪烁显像正常。还对6例原位心脏移植后完全心脏去神经支配患者心脏的MIBG摄取情况进行了研究。MIBG闪烁显像重建为靶心图,并分为8个相等的扇区。在每个扇区内,定义了代表心尖、两个心室中部和基底区域的4个区域。与患有室上性心动过速的年轻受试者(1124.4±317.6)相比,冠状动脉解剖结构正常的老年受试者组(1218.2±198.4)计数减少(F = 15.0,自由度 = 1,p < 0.001)。通过协方差分析对年龄进行调整后,差异消失(p = 0.2)。扫描不同扇区内的计数存在差异(F = 5.7,自由度 = 7,p < 0.001),外侧和前侧扇区的计数高于间隔和下侧扇区。扫描区域内的计数(F = 0.04,自由度 = 3,无显著性差异[NS])或扇区内不同区域的计数(F = 1.1,自由度 = 21,NS)均无差异。在一些扫描中,观察到靶心图10点钟区域的计数略有减少(约10%)。(摘要截断于250字)

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验