Suppr超能文献

用于脑室造影的锝-99m标记人血清白蛋白:六种标记试剂盒的比较评估

Technetium-99m labelled human serum albumin for ventriculography: a comparative evaluation of six labelling kits.

作者信息

Vanbilloen H P, Verbeke K A, De Roo M J, Verbruggen A M

机构信息

Laboratory of Radiopharmaceutical Chemistry, I.F.W., K.U. Leuven, Belgium.

出版信息

Eur J Nucl Med. 1993 Jun;20(6):465-72. doi: 10.1007/BF00175158.

Abstract

In this study we have compared the characteristics of six labelling kits for the preparation of technetium-99m labelled human serum albumin (99mTc-HSA) and evaluated the usefulness of the various 99mTc-HSA preparations as blood pool tracer agents. The amount of the principal ingredients, i.e. HSA and stannous ions, varies largely between the studied kits and this is probably a reason for the observed differences in the labelling rate. Analysis of the reaction mixtures after labelling of the respective kits with 99mTc showed in each preparation the presence of four to five radioactive components in variable relative amounts. The retention time of the main component on size-exclusion high-performance liquid chromatography (SEC-HPLC) was identical for all preparations. Biodistribution of the HPLC-isolated fractions was studied in mice. The components with the shortest and longest retention times on HPLC show poor retention in the plasma. The three intermediate fractions, including the principal peak, are initially retained relatively well in the blood (60%-70% of the injected dose after 10 min), but clearly to a lower degree than iodine-125 labelled HSA. Moreover, they diffuse out of the vascular compartment at a much higher rate than 125I-HSA. The biological behaviour of the main component of the various preparations was clearly different, despite the identical retention time on SEC-HPLC. Study of the total preparations in mice and a rabbit showed that two of them are cleared rapidly from the blood and cannot be considered valuable blood pool tracers. Diffusion of the other preparations out of the blood is slower but also considerable and compromises their use for ventriculography.

摘要

在本研究中,我们比较了六种用于制备锝-99m标记人血清白蛋白(99mTc-HSA)的标记试剂盒的特性,并评估了各种99mTc-HSA制剂作为血池示踪剂的实用性。所研究的试剂盒中主要成分即HSA和亚锡离子的量差异很大,这可能是观察到标记率存在差异的一个原因。用99mTc标记各个试剂盒后对反应混合物进行分析,结果显示每种制剂中都存在四到五种放射性成分,其相对含量各不相同。所有制剂中主要成分在尺寸排阻高效液相色谱(SEC-HPLC)上的保留时间相同。对HPLC分离的级分在小鼠体内的生物分布进行了研究。在HPLC上保留时间最短和最长的成分在血浆中的保留情况较差。包括主峰在内的三个中间级分最初在血液中的保留相对较好(10分钟后为注射剂量的60%-70%),但明显低于碘-125标记的HSA。此外,它们从血管腔中扩散出去的速度比125I-HSA快得多。尽管在SEC-HPLC上的保留时间相同,但各种制剂主要成分的生物学行为明显不同。对小鼠和一只兔子体内的总制剂进行研究表明,其中两种制剂从血液中清除迅速,不能被视为有价值的血池示踪剂。其他制剂从血液中的扩散较慢,但也相当可观,这影响了它们在心室造影中的应用。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验