Marin M L, Veith F J, Panetta T F, Cynamon J, Barone H, Schonholz C, Parodi J C
Division of Vascular Surgery, Montefiore Medical Center/Albert Einstein College of Medicine, New York, NY 10467.
J Vasc Surg. 1993 Aug;18(2):299-302.
This case report describes a new approach to repair a femoral arteriovenous fistula with a transluminally placed intraarterial graft-covered stent. A balloon-expandable stented polytetrafluoroethylene graft was inserted percutaneously to obliterate an arteriovenous fistula after a bullet injured the left superficial femoral artery and vein of an 18-year-old man. Follow-up duplex ultrasonography at 5 months demonstrated patency and luminal integrity of the involved artery and vein, with resolution of the associated pseudoaneurysm. Additional follow-up will be needed to further substantiate the utility of this minimally invasive procedure in the treatment of traumatic arterial injuries.