Wilkins R H, Albin M S
Surg Neurol. 1977 Feb;7(2):71-2.
Embolism of air into the venous system occurs during approximately 25% of neurosurgical operations performed with the patient in the sitting position. The present report calls attention to an unusual entry site for such air embolism-the punctures in the scalp made by a neurosurgical pin-type head holder.
在大约25%的患者处于坐位进行的神经外科手术过程中会发生空气栓塞进入静脉系统的情况。本报告提请注意这种空气栓塞的一个不寻常的进入部位——神经外科针型头架在头皮上造成的穿刺处。