Holmström H, Kahnberg K E, Lessard L
Department of Plastic Surgery, University of Göteborg, Sahlgrenska Hospital, Sweden.
Scand J Plast Reconstr Surg Hand Surg. 1993;27(2):109-12. doi: 10.3109/02844319309079792.
Ten patients with microgenia had their chins augmented with HTR polymer implants. The implants were inserted intraorally and fixed rigidly with a titanium screw. The postoperative course was uneventful except in one patient who had wound dehiscence and was resutured. This patient and all the others were clinically and radiographically stable at one year follow up.
10例小下颌患者采用HTR聚合物植入物进行颏部填充。植入物经口内插入,并用钛螺钉牢固固定。除1例患者出现伤口裂开并再次缝合外,术后过程顺利。在1年的随访中,该患者及其他所有患者在临床和影像学上均保持稳定。