Ohkuma K, Hisa N, Futei S, Takeda T, Nakatsuka S, Hisazumi H, Narimatsu Y, Hiramatsu K
Department of Diagnostic Radiology, Keio University, School of Medicine.
Nihon Igaku Hoshasen Gakkai Zasshi. 1993 Jul 25;53(7):856-8.
Blood flow measurement was performed in 58 kidneys of healthy persons. Detection rate, maximum flow velocity (Vmax), pulsatility index (PI) and resistive index (RI) were measured at main renal artery, segmental artery, interlobar artery and interlobular artery with 2 D-Doppler ultrasound machines. Detection rate was highest at interlobar artery. Vmax and PI tended to fall down with arterial branching. Interlobular artery was usually not visualized by color flow mapping, but sometimes well visualized using Acuson machines. Additional measurement of interlobar and interlobular arteries were performed in such 15 cases, and the result was essentially equal to the above mentioned study.
对58名健康人的肾脏进行了血流测量。使用二维多普勒超声仪在肾主动脉、段动脉、叶间动脉和小叶间动脉测量检测率、最大流速(Vmax)、搏动指数(PI)和阻力指数(RI)。叶间动脉的检测率最高。Vmax和PI往往随着动脉分支而下降。小叶间动脉通常通过彩色血流图无法显示,但有时使用Acuson仪器能很好地显示。在15例此类病例中对叶间动脉和小叶间动脉进行了额外测量,结果与上述研究基本相同。