Minakuchi K, Tamaoka K, Nishio H, Matsuo R, Takada K, Morimoto A, Toyoshima M, Murata K, Onoyama Y
Department of Radiology, Osaka City University Medical School, Japan.
Radiat Med. 1993 Mar-Apr;11(2):43-8.
Intra-arterial digital subtraction portography (IA-DSP) with a blood-isotonic, non-ionic, dimeric contrast medium was carried out in 27 patients with hepatocellular carcinoma. It was possible to obtain images of excellent or good quality of the portal vein and its bilateral main branches in all patients. The third-order branches of the portal vein in the right lobe could be identified in all patients, and images of excellent or good quality were obtained in a mean of 80.2% of patients. Images of third-order branches in the left lobe were of lower quality than those of third-order branches in the right lobe; in particular, images obtained were of poor quality for 27.3% of the medial branches of the left lobe. It was impossible to identify the caudal branches in almost all patients. The side effects of IA-DSP, pain and sensations of heat were very mild: only one patient complained of mild pain, while 18 patients (69.2%) complained of no sensations of heat whatsoever.