The development of a radioreceptor assay (RRA) that can measure serum LH in a variety of species and CG in sera and urine of pregnant women and monkeys is reported. Using sheep luteal membrane as the receptor source and 125I-labeled hLH/hCG as the tracer, dose-response (displacement) curves were obtained using hLH or hCG as standard. The addition of LH-free serum (200 microliters per tube) had no affect on the standard displacement curve. The assay is simple, requires less than 90 min to complete and provides reproducible results. The sensitivity of the assay was 0.6 ng hLH per tube and the intra- and interassay variations were 9.6 and 9.8, respectively. Sera obtained from male and female bonnet monkeys (Macaca radiata) and monkey pituitary extract showed parallelism to the standard curve. The concentrations of LH measured correlated with the physiological status of the animals. Sera of rats, rabbits, hamsters, guinea-pigs, sheep and humans showed parallelism to the hLH standard curve indicating the viability of the RRA to measure serum LH of different species. Since the receptors recognize LH and CG, detection of pregnancy in monkeys and women was possible using this assay. The sensitivity of the assay of hCG was 8.7 miu per tube. This RRA could be a convenient alternative to the Leydig cell bioassay for obtaining the LH bioactivity profile of sera and biological fluids.
据报道,已开发出一种放射受体分析方法(RRA),该方法可测量多种物种的血清促黄体生成素(LH)以及孕妇和猴子血清及尿液中的人绒毛膜促性腺激素(CG)。以绵羊黄体膜作为受体来源,用125I标记的人促黄体生成素/人绒毛膜促性腺激素(hLH/hCG)作为示踪剂,以hLH或hCG为标准品获得剂量反应(置换)曲线。加入无LH血清(每管200微升)对标准置换曲线无影响。该分析方法简单,完成时间少于90分钟,且结果具有可重复性。该分析方法的灵敏度为每管0.6纳克hLH,批内和批间变异系数分别为9.6和9.8。从成年雄性和雌性圆帽猴(食蟹猴)以及猴垂体提取物中获得的血清与标准曲线呈平行关系。所测LH浓度与动物的生理状态相关。大鼠、兔子、仓鼠、豚鼠、绵羊和人类的血清与hLH标准曲线呈平行关系,表明该RRA可用于测量不同物种的血清LH。由于该受体可识别LH和CG,因此使用该分析方法可检测猴子和人类是否怀孕。hCG分析方法的灵敏度为每管8.7毫国际单位。对于获取血清和生物体液的LH生物活性谱而言,这种RRA可能是莱迪希细胞生物测定法的一种便捷替代方法。