Carbon monoxide and oxygen concentrations were measured in seventy-two structural fires using a personal air sampler carried by working firefighters. In a total sampling time of 1329 minutes the carbon monoxide concentration exceeded 500 ppm approximately 29 percent of the time. The maximum carbon monoxide concentration was 27,000 ppm and in 10 percent of the fires, the maximum concentration exceeded 5500 ppm. Only six runs indicated oxygen concentrations less than 18 percent. On the basis of these exposure data, a minimum protection factor of 100 is proposed for breathing apparatus for structural firefighting.

摘要

使用在职消防员携带的个人空气采样器,对72起建筑火灾中的一氧化碳和氧气浓度进行了测量。在总计1329分钟的采样时间里,一氧化碳浓度约有29%的时间超过500 ppm。一氧化碳的最高浓度为27,000 ppm,在10%的火灾中,最高浓度超过了5500 ppm。只有6次测量显示氧气浓度低于18%。基于这些暴露数据,建议用于建筑火灾扑救的呼吸设备的最低防护系数为100。