Söder P O, Jin L J, Söder B
Department of Periodontology, School of Dentistry, Karolinska Institutet, Stockholm, Sweden.
Scand J Dent Res. 1993 Feb;101(1):21-5. doi: 10.1111/j.1600-0722.1993.tb01640.x.
A computerized planimetric method for plaque area measurement has been developed. Using a computerized image analysis system (CIAS), the plaque area and tooth area on color slides were digitized and the number of pixels automatically counted. The proposed Plaque Percent Index (P% Index) expresses plaque area as a percentage of tooth area. The reproducibility of this method was tested and the influence of photographic technique on the P% Index was determined. The association of the Turesky modified Quigley-Hein plaque index (Q-H Index) and the P% Index was assessed. The present method was highly reproducible for the P% Index with an intraexaminer variation of 0.28% and intraexaminer correlation coefficient of 0.99. The results show that highly reproducible P% Index values with an error of less than 3.0% were obtained when the photographs were taken under the following conditions. For the buccal surfaces of anterior teeth, the slides were photographed within a 20-degree range in the horizontal plane and a 30-degree range in the vertical plane; and for the lingual/palatal surfaces of anterior teeth and the buccal or lingual/palatal surfaces of posterior teeth, the slides were photographed with an image of the whole tooth surfaces in the photographic mirrors. The comparison of the Q-H Index and the P% Index revealed that for each score of the Q-H Index the corresponding values of P% Index were wide with a significant crossover value, although a strongly positive correlation was found between the Q-H Index and the P% Index (r = 0.92, P < 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)
已开发出一种用于测量菌斑面积的计算机平面测量方法。使用计算机图像分析系统(CIAS),对彩色幻灯片上的菌斑面积和牙齿面积进行数字化处理,并自动计算像素数量。所提出的菌斑百分比指数(P%指数)将菌斑面积表示为牙齿面积的百分比。测试了该方法的可重复性,并确定了摄影技术对P%指数的影响。评估了Turesky改良的Quigley-Hein菌斑指数(Q-H指数)与P%指数之间的关联。本方法对于P%指数具有高度可重复性,检查者内变异为0.28%,检查者内相关系数为0.99。结果表明,在以下条件下拍摄照片时,可获得误差小于3.0%的高度可重复的P%指数值。对于前牙的颊面,幻灯片在水平面20度范围内和垂直面30度范围内拍摄;对于前牙的舌/腭面以及后牙的颊面或舌/腭面,幻灯片在摄影镜中以整个牙齿表面的图像进行拍摄。Q-H指数与P%指数的比较显示,尽管Q-H指数与P%指数之间存在强正相关(r = 0.92,P < 0.01),但对于Q-H指数的每个分数,P%指数的相应值范围较宽且有显著的交叉值。(摘要截短于250字)