• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Laparoscopic evaluation of the argon beam coagulator. Initial report.

作者信息

Daniell J, Fisher B, Alexander W

机构信息

Department of Obstetrics and Gynecology, Centennial Medical Center, Nashville, Tennessee.

出版信息

J Reprod Med. 1993 Feb;38(2):121-5.

PMID:8445602
Abstract

The objective of this study was to evaluate the safety and hemostatic properties of the argon beam coagulator (ABC) at laparoscopy. The study is composed of two parts: laparoscopic results in five anesthetized animals and a preliminary clinical trial in 35 volunteers undergoing laparoscopy. Animals were evaluated during a laparoscopic cholecystectomy training course. Private patients undergoing operative laparoscopy voluntarily consented to a hospital Investigational Review Board-approved protocol to evaluate the ABC. The pigs were 3-month-old, healthy females. The patients were healthy volunteers undergoing laparoscopy for pain, infertility or cholecystectomy. Both pigs and human volunteers underwent operative laparoscopic use of the ABC for hemostasis and selected tissue electrocoagulation using a prototype 10-mm laparoscopic probe. The safety of the ABC was evaluated in the pigs by continuously monitoring heart rate, oxygen saturation and end-tidal CO2. Patients had similar clinical monitoring during operative laparoscopy, with observation of tissue effects of the ABC for hemostasis and tissue electrocoagulation. Laparoscopic use of the ABC in animals and patients produced no observable anesthetic changes, with both pigs and patients recovering normally. The ABC allowed smokeless, hemostatic tissue electrocoagulation, with a rapid non-touching technique easy to apply laparoscopically. We conclude that the ABC can safely be used laparoscopically with excellent hemostasis and effective controlled tissue electrocoagulation. The lack of smoke and the non-touching technique for delivery allow rapid laparoscopic application. The prototype 10-mm delivery probe is cumbersome, and the argon gas flow rate of 4 L/min with firing requires constant venting of the peritoneum with close monitoring of intraperitoneal pressures.

摘要

相似文献

1
Laparoscopic evaluation of the argon beam coagulator. Initial report.
J Reprod Med. 1993 Feb;38(2):121-5.
2
Efficacy of the argon beam coagulator alone in obtaining hemostasis after laparoscopic porcine heminephrectomy: a pilot study.
Can J Urol. 2008 Jun;15(3):4091-6.
3
[Laparoscopic cholecystectomy using argon bistoury].
G Chir. 1992 Apr;13(4):163-4.
4
The electrophysiologic and histologic effects of the Argon Beam Coagulator on peripheral nerves.
Laryngoscope. 1992 Nov;102(11):1263-7. doi: 10.1288/00005537-199211000-00012.
5
[Non-contact argon gas coagulation in flexible endoscopy of the gastrointestinal tract: in vitro studies and initial clinical experiences].[非接触式氩气凝固术在胃肠道软性内镜检查中的应用:体外研究及初步临床经验]
Z Gastroenterol. 1995 Dec;33(12):694-700.
6
Comparison of ultrasonic scalpel versus argon-beam and conventional electrocautery for internal thoracic artery dissection.超声刀与氩束刀及传统电刀用于胸廓内动脉解剖的比较。
Thorac Cardiovasc Surg. 2002 Apr;50(2):71-3. doi: 10.1055/s-2002-26703.
7
Feasibility of laparoscopic debulking with electrosurgical loop excision procedure and argon beam coagulator at recurrence in patients with previous laparotomy debulking.对于既往接受过剖腹减瘤手术的患者,在复发时采用电外科环形切除术和氩离子束凝固器进行腹腔镜减瘤手术的可行性。
Am J Obstet Gynecol. 2004 May;190(5):1394-7. doi: 10.1016/j.ajog.2004.02.034.
8
Development and initial trial of the minilaparoscopic argon coagulator.迷你腹腔镜氩气凝固器的研制与初步试验
J Laparoendosc Adv Surg Tech A. 2000 Apr;10(2):93-9. doi: 10.1089/lap.2000.10.93.
9
[Post-tonsillectomy hemostasis: a prospective, randomized, double-blind study comparing argon beam coagulation and monopolar electrocoagulation].
Harefuah. 2006 Aug;145(8):554-6, 632.
10
Death during laparoscopy: can 1 gas push out another? Danger of argon electrocoagulation.腹腔镜手术中的死亡:一种气体能排出另一种气体吗?氩气电凝的危险。
Surg Laparosc Endosc Percutan Tech. 2008 Aug;18(4):395-7. doi: 10.1097/SLE.0b013e318172b4fd.

引用本文的文献

1
Hemostasis in laparoscopic renal surgery.腹腔镜肾手术中的止血
Indian J Urol. 2012 Jan;28(1):3-8. doi: 10.4103/0970-1591.94939.
2
Use of neutral argon plasma in the laparoscopic treatment of endometriosis.中性氩等离子体在腹腔镜子宫内膜异位症治疗中的应用。
JSLS. 2009 Oct-Dec;13(4):479-83. doi: 10.4293/108680809X12589998403967.
3
Argon plasma coagulation for successful treatment of early gastric cancer with intramucosal invasion.氩离子凝固术成功治疗早期胃癌黏膜内浸润
Gut. 2003 Mar;52(3):334-9. doi: 10.1136/gut.52.3.334.