Suppr超能文献

使用动态磁共振成像测量猫短暂性缺血后脑血管变化

Measurement of cerebrovascular changes in cats after transient ischemia using dynamic magnetic resonance imaging.

作者信息

Hamberg L M, Macfarlane R, Tasdemiroglu E, Boccalini P, Hunter G J, Belliveau J W, Moskowitz M A, Rosen B R

机构信息

Massachusetts General Hospital NMR Center, Department of Radiology, Charlestown 02129.

出版信息

Stroke. 1993 Mar;24(3):444-50; discussion 450-1. doi: 10.1161/01.str.24.3.444.

Abstract

BACKGROUND AND PURPOSE

Hemodynamic changes associated with acute ischemia cannot be measured with conventional nuclear magnetic resonance imaging. In this study, we used dynamic susceptibility-contrast magnetic resonance imaging to measure the changes in vascular transit time and relative cerebral blood volume in a feline occlusion-reperfusion model.

METHODS

Dynamic susceptibility-contrast measurements were obtained before and during 10 minutes of global cerebral ischemia and for up to 3 hours after the onset of reperfusion. A cerebral blood flow index was calculated from the vascular transit time and relative cerebral blood volume measurements. Functional maps were constructed to demonstrate the regional hemodynamic differences resulting from the induced ischemia.

RESULTS

During the early phase after reperfusion, both the relative cerebral blood volume and blood flow index rose sharply, followed by a fall to near-basal levels at 45 minutes (1 x control and 1.3 x control, respectively). Thereafter, the volume rose slowly, whereas the flow index continued to drop. At 3 hours, cerebral blood volume had reached 1.6 times its control value, whereas the flow index had returned to its base value.

CONCLUSIONS

The hemodynamic behavior we observed in our model reflects the independent responses of the cerebral blood volume and flow index to ischemic insult. Measurements acquired by our method were consistent with the temporal behavior reported in previous radionuclide studies. Susceptibility-contrast nuclear magnetic resonance tomographic imaging proved to be valuable in detecting and quantifying both immediate and subsequent changes in the hemodynamic state of the ischemic and hyperemic feline brain.

摘要

背景与目的

急性缺血相关的血流动力学变化无法通过传统核磁共振成像进行测量。在本研究中,我们使用动态磁敏感对比磁共振成像来测量猫闭塞-再灌注模型中血管通过时间和相对脑血容量的变化。

方法

在全脑缺血10分钟期间及再灌注开始后长达3小时内,获取动态磁敏感对比测量值。根据血管通过时间和相对脑血容量测量值计算脑血流指数。构建功能图以展示由诱导缺血导致的区域血流动力学差异。

结果

在再灌注后的早期阶段,相对脑血容量和血流指数均急剧上升,随后在45分钟时降至接近基础水平(分别为对照值的1倍和1.3倍)。此后,血容量缓慢上升,而血流指数持续下降。在3小时时,脑血容量达到其对照值的1.6倍,而血流指数已恢复至基础值。

结论

我们在模型中观察到的血流动力学行为反映了脑血容量和血流指数对缺血性损伤的独立反应。我们方法获得的测量结果与先前放射性核素研究报道的时间行为一致。磁敏感对比核磁共振断层成像被证明在检测和量化缺血和充血猫脑血流动力学状态的即时和后续变化方面具有价值。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验