Suppr超能文献

经皮线圈填塞术闭合高流量冠状动脉瘘

High flow coronary fistula closure by percutaneous coil packing.

作者信息

Lacombe P, Rocha P, Marchand X, Mulot R, Rigaud M, Jondeau G, Weber J M, Kahn J C

机构信息

Radiology Department, West Paris University Hospitals, France.

出版信息

Cathet Cardiovasc Diagn. 1993 Apr;28(4):342-6. doi: 10.1002/ccd.1810280415.

Abstract

Few cases of transcatheter coronary fistula closure have been reported. High flow coronary fistulae are usually treated by surgery. This case report presents a 5.4 liters/min flow coronary fistula percutaneously closed by steel coils. This large flow needed the packing of 25 coils, 10-15 cm long, for its total occlusion.

摘要

经导管冠状动脉瘘封堵的病例报道较少。高流量冠状动脉瘘通常采用手术治疗。本病例报告介绍了一例通过钢圈经皮封堵流量为5.4升/分钟的冠状动脉瘘。如此大的流量需要填充25个长度为10 - 15厘米的钢圈才能完全封堵。