Abstract

The effects of using an automated compounder for adding ingredients to parenteral nutrient (PN) base solutions was evaluated. Work-sampling methods were used to determine the amount of time spent by pharmacists and technicians in the production of PN solutions before and after the implementation of an automated device for adding ingredients to PN base solutions. Costs of materials and supplies were evaluated before and after the PN compounder was implemented. Qualitative (sterility) and quantitative (accuracy) analyses were performed by the hospital laboratory. A personnel time savings of 5.4 minutes per PN solution (1.0 full-time equivalent [FTE]) was shown. There was also an additional 0.5 FTE saved in activities not directly related to PN production. There was a 1.5% increase in pharmacist time (mean +/- S.D. preimplementation, 12.66 +/- 2.33 minutes; postimplementation, 12.85 +/- 1.96 minutes) and a significant 27.9% decrease in technician time (mean +/- S.D. preimplementation, 20.29 +/- 2.47 minutes; postimplementation, 14.62 +/- 2.24 minutes) per PN solution. The break-even point for personnel and supply costs was 33 PN solutions. Qualitative analysis resulted in one positive culture preimplementation and no positive cultures postimplementation. Quantitative analysis showed an improvement in compounding accuracy. The use of an automated compounder for adding ingredients to PN base solutions resulted in personnel time savings and improved accuracy.

摘要

评估了使用自动配药器向肠外营养(PN)基础溶液中添加成分的效果。采用工作抽样方法来确定在实施用于向PN基础溶液中添加成分的自动化设备之前和之后,药剂师和技术人员在生产PN溶液时所花费的时间量。在实施PN配药器之前和之后评估了材料和用品的成本。由医院实验室进行定性(无菌)和定量(准确性)分析。结果表明,每制备一份PN溶液可节省5.4分钟的人工时间(相当于1.0个全时当量[FTE])。在与PN生产无直接关系的活动中还额外节省了0.5个FTE。每份PN溶液的药剂师时间增加了1.5%(实施前均值±标准差,12.66±2.33分钟;实施后,12.85±1.96分钟),而技术人员时间显著减少了27.9%(实施前均值±标准差,20.29±2.47分钟;实施后,14.62±2.24分钟)。人员和供应成本的盈亏平衡点是33份PN溶液。定性分析显示实施前有一次培养呈阳性,实施后无培养呈阳性。定量分析表明配药准确性有所提高。使用自动配药器向PN基础溶液中添加成分可节省人工时间并提高准确性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验