Suppr超能文献

二维超声心动图中冠状动脉血流对心肌灰度幅度的影响:一项实验研究。

Effects of coronary blood flow on myocardial grey level amplitude in two dimensional echocardiography: an experimental study.

作者信息

Marini C, Ghelardini G, Picano E, Rovai D, Lombardi M, Trivella M G, Distante A, L'Abbate A

机构信息

CNR, Institute of Clinical Physiology, Pisa, Italy.

出版信息

Cardiovasc Res. 1993 Feb;27(2):279-83. doi: 10.1093/cvr/27.2.279.

Abstract

OBJECTIVE

The aims were: (1) to evaluate whether differences in absolute and cyclic echocardiographic image amplitude exist in different layers (subendocardium and subepicardium) and regions (septal, anterior, lateral, inferior wall) of the canine left ventricle; (2) to assess the dependence of these variables upon local variations of coronary blood flow.

METHODS

In six anaesthetised open chest dogs the circumflex coronary artery was cannulated and perfused by a roller pump with blood from their own femoral artery. Maximum coronary vasodilatation was obtained by continuous adenosine infusion. The absolute values and the transmural distribution of coronary blood flow were measured by radionuclide labelled microspheres. Echo images were obtained in short axis view by a commercially available electronic sector scanner with a 5.0 MHz transducer directly placed on the epicardial surface of the right ventricle, and digitised off-line into a matrix of 256 x 256 pixels with 25% grey level per pixel. The average grey level was calculated for each region of interest.

RESULTS

In 32 different conditions, circumflex flow ranged from 0.80 to 12.89 ml.min-1.g-1 and the endocardial/epicardial ratio of flow from 0.53 to 1.73. In the circumflex region (subjected to flow changes) segmental amplitude varied from 76(SD 20) (end diastole) to 56(18) (end systole), p < 0.001. In all regions, a consistent cyclic variation was found, ranging from 9(14) to 28(16)%. For all levels of flow, subendocardial and subepicardial regions showed similar values of both absolute amplitude and cyclic variation. No significant relationship was found between transmural distribution of blood flow and either segmental amplitude (r = 0.26) or cyclic variation (r = 0.04).

CONCLUSIONS

(1) a consistent cyclic grey level variation is present in all regions of the canine left ventricle, but subendocardial and subepicardial layers show similar values of both absolute amplitude and cyclic variation; (2) in the absence of severe underperfusion and echocardiographically detectable dyssynergy, absolute amplitude and cyclic variation are totally unrelated to changes in coronary blood flow.

摘要

目的

本研究旨在:(1)评估犬左心室不同层(心内膜下和心外膜下)和区域(室间隔、前壁、侧壁、下壁)的绝对和周期性超声心动图图像幅度是否存在差异;(2)评估这些变量对冠状动脉血流局部变化的依赖性。

方法

对6只麻醉开胸犬,将左旋冠状动脉插管,并用滚轴泵用来自其自身股动脉的血液进行灌注。通过持续输注腺苷获得最大冠状动脉血管舒张。用放射性核素标记的微球测量冠状动脉血流的绝对值和跨壁分布。通过商用电子扇形扫描仪在短轴视图中获取回声图像,该扫描仪配有5.0 MHz换能器,直接放置在右心室的心外膜表面,并离线数字化为256×256像素的矩阵,每个像素具有25%的灰度级。计算每个感兴趣区域的平均灰度级。

结果

在32种不同条件下,左旋冠状动脉血流范围为0.80至12.89 ml·min-1·g-1,心内膜/心外膜血流比值为0.53至1.73。在左旋冠状动脉区域(血流发生变化),节段幅度从舒张末期的76(标准差20)变化到收缩末期的56(18),p<0.001。在所有区域,均发现一致的周期性变化,范围为9(14)至28(16)%。对于所有血流水平,心内膜下和心外膜下区域在绝对幅度和周期性变化方面均显示出相似的值。未发现血流跨壁分布与节段幅度(r = 0.26)或周期性变化(r = 0.04)之间存在显著关系。

结论

(1)犬左心室所有区域均存在一致的周期性灰度级变化,但心内膜下和心外膜下层在绝对幅度和周期性变化方面均显示出相似的值;(2)在没有严重灌注不足和超声心动图可检测到的协同失调的情况下,绝对幅度和周期性变化与冠状动脉血流变化完全无关。