Autoregulation of regional cerebral blood flow was evaluated in cats. In normal baseline situations autoregulation was invariably present. Concomitant to an enlarging mass, supratentorial loss of this protective mechanism was seen both ipsilateral and contralateral to the mass. There was relative preservation of midbrain autoregulation until very high balloon volumes were reached. There was no acute regulation upon balloon deflation.
在猫身上评估了局部脑血流量的自动调节。在正常基线情况下,自动调节总是存在的。随着肿块增大,在肿块同侧和对侧均可见幕上这种保护机制的丧失。直到达到非常高的球囊容量时,中脑的自动调节才相对得以保留。球囊放气时没有急性调节。