• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Total respiratory input impedance with the upper airway wall shunt minimized.

作者信息

Habib R H, Jackson A C

机构信息

Department of Biomedical Engineering, Boston University, Massachusetts 02215.

出版信息

J Appl Physiol (1985). 1993 Mar;74(3):1045-55. doi: 10.1152/jappl.1993.74.3.1045.

DOI:10.1152/jappl.1993.74.3.1045
PMID:8482641
Abstract

Respiratory impedances (Zrs) measured with the cheeks manually supported (Zsc) demonstrate an antiresonance (AR) at approximately 170 Hz, whereas those measured with the head generator (Zhg) have an AR at significantly lower frequencies (150 Hz). The differences in the AR between methods were previously attributed to upper airway wall (UAW) shunting in Zsc, and Zhg was believed to represent shunt-free impedance. To test this hypothesis, we measured four independent estimates of Zrs (4-256 Hz) in five healthy adults. Applying the oscillations at the mouth, we measured Zrs with the cheeks unsupported (Zuc) and when the subject's head and neck were enclosed in a rigid chamber completely filled with water (Zwa). We also measured Zhg with the oscillations applied around the head. Because water is incompressible, Zwa should minimize UAW shunt if not completely eliminate it. There were no significant differences in any of the AR features (e.g., location and bandwidth) of Zuc, Zsc, and Zwa. Conversely, all AR features of Zwa and Zhg were significantly different. To assess wall motion during both forms of oscillations (i.e., applied at the mouth and around the head), we measured two UAW local impedances by use of accelerometers placed on the cheeks (Zch) and submental (Zsm) region. Above 40 Hz, Zch and Zsm estimates were significantly dependent on the forcing method. Furthermore, Zch and Zsm made with the standard oscillations were consistent with the lumped UAW impedances measured with a head plethysmograph, whereas those made with the oscillations around the head were not. Therefore we conclude that, at > 32 Hz, Zsc more closely represents shunt-free impedance than does Zhg and hence should be preferred when Zrs are measured.

摘要

相似文献

1
Total respiratory input impedance with the upper airway wall shunt minimized.
J Appl Physiol (1985). 1993 Mar;74(3):1045-55. doi: 10.1152/jappl.1993.74.3.1045.
2
Impact of frequency range and input impedance on airway-tissue separation implied from transfer impedance.从转移阻抗推断频率范围和输入阻抗对气道-组织分离的影响。
J Appl Physiol (1985). 1993 Mar;74(3):1089-99. doi: 10.1152/jappl.1993.74.3.1089.
3
Human respiratory impedance from 8 to 256 Hz corrected for upper airway shunt.针对上呼吸道分流进行校正后的8至256赫兹人体呼吸阻抗。
J Appl Physiol (1985). 1989 Nov;67(5):1973-81. doi: 10.1152/jappl.1989.67.5.1973.
4
Input respiratory impedance measured by head generator in preschool children.学龄前儿童头部发生器测量的输入呼吸阻抗。
Pediatr Pulmonol. 2000 Jul;30(1):47-55. doi: 10.1002/1099-0496(200007)30:1<47::aid-ppul8>3.0.co;2-w.
5
Respiratory input impedance up to 256 Hz in healthy humans breathing foreign gases.
J Appl Physiol (1985). 1993 Jul;75(1):307-20. doi: 10.1152/jappl.1993.75.1.307.
6
Partitioning of airway and respiratory tissue mechanical impedances by body plethysmography.通过体容积描记法对气道和呼吸组织机械阻抗进行分区
J Appl Physiol (1985). 1998 Feb;84(2):553-61. doi: 10.1152/jappl.1998.84.2.553.
7
Input respiratory impedance to estimate airway hyperreactivity in children: standard method versus head generator.通过输入呼吸阻抗评估儿童气道高反应性:标准方法与头部发生器法对比
Eur Respir J. 1994 Mar;7(3):601-7. doi: 10.1183/09031936.94.07030601.
8
Influence of upper airway shunt on total respiratory impedance in infants.
J Appl Physiol (1985). 1999 Sep;87(3):902-9. doi: 10.1152/jappl.1999.87.3.902.
9
Respiratory impedance measured with head generator to minimize upper airway shunt.
J Appl Physiol (1985). 1985 Dec;59(6):1790-5. doi: 10.1152/jappl.1985.59.6.1790.
10
Volume dependence of high-frequency respiratory mechanics in healthy adults.
Ann Biomed Eng. 2008 Jan;36(1):162-70. doi: 10.1007/s10439-007-9391-x. Epub 2007 Oct 18.