Amarasena G A, Parry A J, Johnston B, Pillai R
Oxford Heart Centre, John Radcliffe Hospital, United Kingdom.
Ann Thorac Surg. 1993 Jun;55(6):1566-7. doi: 10.1016/0003-4975(93)91113-2.
An 81-year-old woman presented with acute aortic regurgitation in the setting of an aneurysm of the ascending aorta and arch. The aortic valve, ascending aorta, and arch were replaced with a composite graft during continuous hypothermic total-body perfusion. Continuous cerebral perfusion was carried out by low-pressure retrograde perfusion via the superior vena cava while perfusion of the lower body was maintained via a femoral arterial cannula.