Chen X H, Hommerson A L, Zweipfenning P G, Franke J P, Harmen-Boverhof C W, Ensing K, de Zeeuw R A
University Centre for Pharmacy, Department of Analytical Chemistry and Toxicology, Groningen, The Netherlands.
J Forensic Sci. 1993 May;38(3):668-76.
The use of Bond Elut Certify columns for the isolation of morphine from whole blood was evaluated. In order to monitor possible losses and the elution profile of morphine, a small amount of the tritiated analogue was added to the samples. Four sample pretreatment methods, three protein precipitation methods and one sonication/dilution method, were tested. The latter one gave the best results. The blood sample was applied onto the column at pH 3.3 after sonication and dilution with 0.1 M phosphate buffer (pH 3.3). The retention of morphine was affected by the pH of the samples, and the loss of morphine during sample application was minimized at low pH (3.3). The interferences were removed by washing the column with the phosphate buffer, 0.01 M acetic acid (pH 3.3), and methanol, sequentially. Ammoniated methanol, 2 mL at 2%, was selected to elute morphine. As a result, more than 80% of 3H-morphine was recovered for concentrations of morphine ranging from 5 to 4000 ng/mL.
对使用Bond Elut Certify柱从全血中分离吗啡进行了评估。为监测吗啡可能的损失及洗脱情况,向样品中加入了少量氚标记类似物。测试了四种样品预处理方法,三种蛋白质沉淀法和一种超声处理/稀释法。后者效果最佳。将血样在超声处理并用0.1M磷酸盐缓冲液(pH 3.3)稀释后,于pH 3.3下加样到柱上。吗啡的保留受样品pH值影响,在低pH(3.3)下加样过程中吗啡损失最小。依次用磷酸盐缓冲液、0.01M乙酸(pH 3.3)和甲醇冲洗柱子以去除干扰物。选择2mL 2%的氨化甲醇洗脱吗啡。结果,对于浓度范围为5至4000 ng/mL的吗啡,超过80%的3H-吗啡被回收。