Dauman R, Tyler R S, Aran J M
Audiology Department, Hôpital Pellegrin, CHU Bordeaux, France.
Acta Otolaryngol. 1993 May;113(3):291-5. doi: 10.3109/00016489309135811.
Several reports have indicated that some cochlear implant patients experience a reduction in their tinnitus while listening to noise or speech. In the present study, two patients reporting bilateral tinnitus were selected from a group of adults with the Nucleus cochlear implant. They rated their tinnitus loudness and severity and completed the Tinnitus Handicap Questionnaire. The stimuli for electrical stimulation were charge-balanced pulse trains of various repetition rates (frequencies) and inter-electrode distances. A range of electrodes was chosen in each subject, including basal, medial and apical electrodes. For each condition, the hearing threshold level and the uncomfortable loudness level were determined. A range of stimulus levels between these two values were presented randomly. After each presentation, the patients rated the stimulus loudness and the tinnitus loudness on a 0 to 100 scale. These judgements were used to carefully determine the psychometric function between stimulus level and stimulus loudness, and between stimulus level and tinnitus loudness. All the parameters explored were important for maximizing the relationship between tinnitus reduction and stimulus loudness. First, the effectiveness of electrical stimulation in tinnitus reduction depended on the place along the cochlear partition. Second, a pulse rate of 125 Hz showed the greatest efficiency in terms of the current level needed to suppress tinnitus. Third, these two subjects showed rather poor performances in speech perception when using their speech processor in the usual condition and the hypothesis of an influence from tinnitus annoyance is suggested in addition to some more classical predicting factors of speech recognition in cochlear implant users.
多项报告表明,一些人工耳蜗植入患者在听噪音或语音时耳鸣症状有所减轻。在本研究中,从一组使用Nucleus人工耳蜗的成年患者中选取了两名报告双侧耳鸣的患者。他们对自己耳鸣的响度和严重程度进行了评分,并完成了耳鸣障碍问卷。电刺激的刺激源是不同重复率(频率)和电极间距离的电荷平衡脉冲序列。在每个受试者中选择了一系列电极,包括基底电极、中间电极和顶端电极。对于每种情况,确定听力阈值水平和不适响度水平。在这两个值之间随机呈现一系列刺激水平。每次呈现后,患者在0到100的量表上对刺激响度和耳鸣响度进行评分。这些判断用于仔细确定刺激水平与刺激响度之间以及刺激水平与耳鸣响度之间的心理测量函数。所有探索的参数对于最大化耳鸣减轻与刺激响度之间的关系都很重要。首先,电刺激减轻耳鸣的效果取决于沿耳蜗隔板的位置。其次,就抑制耳鸣所需的电流水平而言,125 Hz的脉冲率显示出最高的效率。第三,这两名受试者在正常使用语音处理器时的言语感知表现相当差,除了人工耳蜗使用者言语识别的一些更经典的预测因素外,还提出了耳鸣烦恼影响的假设。