Renal and total dopamine (DA) spillover rates at rest were measured in 25 conscious rabbits with chronically implanted renal vein catheters. Renal DA spillover rate was calculated from veno-arterial difference in plasma free DA concentrations across the kidney corrected by the fractional extraction of infused 3H-DA. Plasma free DA concentrations were 11.0 +/- 2.7 pg/ml in the artery and 14.3 +/- 3.6 in the renal vein. Renal and total DA spillover rates were 0.51 +/- 0.08, 2.61 +/- 0.30 ng/min, respectively, both of which were significantly (p < 0.001) lower than the respective norepinephrine (NE) spillover rates (renal: 16.3 +/- 1.4, total: 39.6 +/- 1.7). The fractional extraction of 3H-DA across the kidney (55 +/- 3%) and the total DA clearance (285 +/- 31 ml/min) were both significantly (p < 0.05) higher than that of 3H-NE (45 +/- 3) and the total NE clearance (198 +/- 9), respectively. The ratio of renal to the total spillover rate of DA (0.23 +/- 0.05) was significantly (p < 0.05) lower than that of NE (0.41 +/- 0.04). These results demonstrate that DA is released into plasma within the kidney and suggest that the measurement of renal DA spillover rate using 3H-DA radiotracer technique is useful to detect resting renal dopaminergic nerve activity.
对25只植入慢性肾静脉导管的清醒家兔测量了静息时肾及总多巴胺(DA)溢出率。肾DA溢出率通过经注入的3H - DA的分数提取校正后的肾脏血浆游离DA浓度的静脉 - 动脉差值来计算。动脉血浆游离DA浓度为11.0±2.7 pg/ml,肾静脉为14.3±3.6 pg/ml。肾及总DA溢出率分别为0.51±0.08、2.61±0.30 ng/min,两者均显著(p < 0.001)低于各自的去甲肾上腺素(NE)溢出率(肾:16.3±1.4,总:39.6±1.7)。3H - DA经肾脏的分数提取(55±3%)和总DA清除率(285±31 ml/min)分别显著(p < 0.05)高于3H - NE(45±3)和总NE清除率(198±9)。肾与总DA溢出率之比(0.23±0.05)显著(p < 0.05)低于NE(0.41±0.04)。这些结果表明DA在肾脏内释放到血浆中,并提示使用3H - DA放射性示踪技术测量肾DA溢出率有助于检测静息时肾多巴胺能神经活性。