Sloet van Oldruitenborgh-Oosterbaan M M, Barneveld A
Department of Large Animal Medicine and Nutrition, Faculty of Veterinary Medicine, Utrecht University, The Netherlands.
Vet Rec. 1995 Aug 5;137(6):136-9. doi: 10.1136/vr.137.6.136.
Six Dutch warmblood horses, ridden by an experienced rider, cantered 3320 m at a speed adapted to the individual horse's anaerobic threshold, under four different conditions: 1, on a firm shell track with the speed varying from 6.5 to 9.4 m/s; 2, on a horizontal treadmill at the same speeds and for the same duration as in test 1; 3, on a horizontal treadmill for the same duration as in tests 1 and 2, but at a 10 per cent higher speed; and 4, on a treadmill at the same speed and for the same duration as in test 1, but at an inclination of 1 to 2 per cent adjusted individually to obtain heart rates similar to those recorded in test 1. On the basis of the heart rates and plasma lactate concentrations, the workload of the horses was significantly greater in the normal exercise test (1) than in the first treadmill test (2). Increasing the speed of the test on the horizontal treadmill by 10 per cent (test 3) resulted in heart rates and plasma lactate concentrations similar to those recorded in test 1. Inclining the treadmill on the basis of the heart rates achieved in test 1 had a less consistent effect than increasing the speed, but imitated a normal exercise test better than the horizontal treadmill test 2.
六匹荷兰温血马由一名经验丰富的骑手驾驭,在四种不同条件下,以适应每匹马无氧阈值的速度慢跑3320米:1. 在坚实的硬壳跑道上,速度在6.5至9.4米/秒之间变化;2. 在水平跑步机上,速度和持续时间与测试1相同;3. 在水平跑步机上,持续时间与测试1和2相同,但速度提高10%;4. 在跑步机上,速度和持续时间与测试1相同,但倾斜度为1%至2%,根据每匹马的情况单独调整,以使心率与测试1中记录的心率相似。根据心率和血浆乳酸浓度,马匹在正常运动测试(1)中的工作量明显大于第一次跑步机测试(2)。将水平跑步机上的测试速度提高10%(测试3),导致心率和血浆乳酸浓度与测试1中记录的相似。根据测试1中达到的心率倾斜跑步机,其效果不如提高速度一致,但比水平跑步机测试2更能模拟正常运动测试。