The application of the Wiener filter to the estimation of responses evoked in the tonic EMG activity of tibialis anterior by cutaneous electrical stimulation of the foot is described. The effectiveness of the filter is assessed using both experimental and simulated data by computing the mean square error between the actual evoked potential and ensemble average and Wiener filter estimates of it. The Wiener filter is shown to provide a better estimate of the final response than simple ensemble averaging. The improvement is most marked in cases where the signal-to-noise ratio is small, but the Wiener filter estimate is always better than the ensemble average estimate. It is concluded that Wiener filtering significantly reduces the number of responses required to obtain a good estimate of the evoked potential in this experimental situation.

摘要

本文描述了维纳滤波器在通过足部皮肤电刺激估计胫前肌紧张性肌电图活动诱发反应中的应用。通过计算实际诱发电位与总体平均值以及维纳滤波器估计值之间的均方误差,使用实验数据和模拟数据评估了滤波器的有效性。结果表明,与简单的总体平均相比,维纳滤波器能更好地估计最终反应。在信噪比小的情况下,这种改进最为明显,但维纳滤波器的估计始终优于总体平均估计。得出的结论是,在这种实验情况下,维纳滤波显著减少了获得诱发电位良好估计所需的反应数量。