Suppr超能文献

卵巢癌患者静脉注射放射性标记的Fab'或F(ab')2片段后的体液抗OV-TL 3反应。

Humoral anti-OV-TL 3 response after the intravenous administration of radiolabelled Fab' or F(ab')2 fragments in ovarian cancer patients.

作者信息

Tibben J G, Thomas C M, Massuger L F, Segers M F, Schijf C P, Corstens F H, Boerman O C

机构信息

Department of Obstetrics and Gynaecology, University Hospital Nijmegen St Radboud, The Netherlands.

出版信息

Nucl Med Commun. 1995 Oct;16(10):853-9. doi: 10.1097/00006231-199510000-00009.

Abstract

The human anti-mouse antibody (HAMA) response was determined in the serum of patients suspected of having ovarian cancer who underwent radioimmunoscintigraphy with either 99Tcm-OV-TL 3 Fab' (n = 20) or 111In-DTPA-OV-TL 3 F(ab')2 (n = 73). Blood samples were collected prior to and at several time points post-intravenous injection. The detection of HAMA was performed with an in-house OV-TL 3 F(ab')2-based sandwich-type immunoradiometric assay (IRMA). The homologous IRMA demonstrated that 8 of 20 (40%) patients had developed HAMA responses after injection of Fab' fragments and that 14 of 73 (19%) patients had developed HAMA responses after F(ab')2 administration. The subclass of the measured HAMA was analysed in a limited number of samples, showing IgG or IgM as well as mixed responses. The kinetics of the HAMA responses varied greatly. Our study showed the relevance of the sampling time and frequency: HAMA responses can be easily underestimated with a low sampling frequency. The homologous IRMA described in this study was able to quantify the OV-TL 3-specific HAMA responses. With additional assays, the subclass of the HAMA could be further analysed. Remarkably, the fraction of HAMA responders after injection of OV-TL 3 Fab' fragments was in the same range as the proportion of HAMA responders after F(ab')2 administration.

摘要

在疑似患有卵巢癌且接受了用99锝-OV-TL 3 Fab'(n = 20)或铟-111-DTPA-OV-TL 3 F(ab')2(n = 73)进行放射免疫闪烁显像的患者血清中测定人抗鼠抗体(HAMA)反应。在静脉注射前及注射后的几个时间点采集血样。采用基于内部OV-TL 3 F(ab')2的夹心型免疫放射分析(IRMA)检测HAMA。同源IRMA显示,20例患者中有8例(40%)在注射Fab'片段后产生了HAMA反应,73例患者中有14例(19%)在给予F(ab')2后产生了HAMA反应。在有限数量的样本中分析了所测HAMA的亚类,显示为IgG或IgM以及混合反应。HAMA反应的动力学差异很大。我们的研究表明了采样时间和频率的相关性:采样频率低时,HAMA反应很容易被低估。本研究中描述的同源IRMA能够定量OV-TL 3特异性HAMA反应。通过其他检测方法,可以进一步分析HAMA的亚类情况。值得注意的是,注射OV-TL 3 Fab'片段后HAMA反应者的比例与给予F(ab')2后HAMA反应者的比例处于同一范围。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验