Development of an intravenous axial flow pump for temporary right heart assist.

作者信息

Nakatani T, Anai H, Wakisaka Y, Taenaka Y, Tatsumi E, Masuzawa T, Baba Y, Eya K, Toda K, Araki K

机构信息

National Cardiovascular Center Research Institute, Osaka, Japan.

出版信息

ASAIO J. 1995 Jul-Sep;41(3):M336-40. doi: 10.1097/00002480-199507000-00026.

Abstract

In clinical settings, quick application systems with easy access for circulatory support are desired. For left heart assist, an intraarterial axial flow pump (Hemopump) has been developed and applied to clinical cases. However, no simple way has been proposed for right heart assist. We have developed an intravenous axial flow pump for temporary right heart assist and have reported its hemodynamic effect. In this study, in vivo evaluation of this system was performed. The pump system consists of an outflow cannula, an impeller that was newly developed for intravenous use, and a driving system for the Hemopump. A prototype pump demonstrated 3.2 L/min of maximal flow at a pressure differential against 40 mmHg at a pump speed of 28,000 rpm in mock circulation. Application to goats is as follows. A 14 mm low porosity graft was anastomosed to the infrarenal inferior vena cava (IVC). The pump system was inserted into the IVC through the graft and advanced to the right heart using balloon catheter guidance under fluoroscopy, and the tip of the cannula of the pump was positioned at the main pulmonary artery. In acute experiments, this system provided effective right heart assist under induced pulmonary stenosis and induced biventricular failure with left ventricular assist. Chronic animal experiments were performed for as long as 4 hr using adult goats weighing 51-54 kg. There were no difficulties in pump insertion. In one goat, the drive shaft was broken because of kinking of the shaft inside the body, caused by failure in securing the pump. Levels of platelet counts and plasma hemoglobin were acceptable, and there was no prominent damage to heart tissues. In conclusion, an intravenous axial flow pump introduced through a peripheral vein is practicable for temporary right heart assist.

摘要

相似文献

1
Development of an intravenous axial flow pump for temporary right heart assist.
ASAIO J. 1995 Jul-Sep;41(3):M336-40. doi: 10.1097/00002480-199507000-00026.
2
In vitro and in vivo assessment of an intravenous axial flow pump for right heart assist.
ASAIO J. 1994 Jul-Sep;40(3):M723-7. doi: 10.1097/00002480-199407000-00093.
4
In vivo evaluation of the "TinyPump" as a pediatric left ventricular assist device.
Artif Organs. 2011 May;35(5):543-53. doi: 10.1111/j.1525-1594.2010.01192.x.
5
Selective reduction of afterload in right heart assist therapy: a mock loop study†.
Interact Cardiovasc Thorac Surg. 2014 Jul;19(1):76-81. doi: 10.1093/icvts/ivu067. Epub 2014 Mar 26.
9
Banding the Right Ventricular Assist Device Outflow Conduit: Is It Really Necessary With Current Devices?
Artif Organs. 2015 Dec;39(12):1055-61. doi: 10.1111/aor.12497. Epub 2015 May 21.
10
Clinical experience with the Hemopump.
ASAIO Trans. 1989 Jul-Sep;35(3):604-6. doi: 10.1097/00002480-198907000-00141.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验