Svoboda S J, Eglseder W A, Belkoff S M
Department of Surgery, University of Maryland School of Medicine, Baltimore, USA.
J Hand Surg Am. 1995 Nov;20(6):980-5. doi: 10.1016/S0363-5023(05)80146-7.
A cadaveric study was undertaken to identify a potential autograft for use in repairing the ruptured scapholunate interosseous ligament. Three ligament complexes (the dorsal metatarsal ligament of the fourth and fifth metatarsals, a dorsal tarsometatarsal ligament, and the dorsal calcaneocuboid ligament) were chosen as autograft candidates. The scapholunate interosseous ligament and the three autograft candidates were harvested as bone-ligament-bone complexes from matched hands and feet of six fresh-frozen male cadavers (age, 51-68 years). The complexes were elongated using a servohydraulic testing machine at a constant grip-to-grip rate of 0.1 mm/s until failure. Stiffness and strength values were calculated and compared for each ligament complex. Analysis indicated that the stiffness values for the tarsometatarsal ligament and the scapholunate interosseous ligament were not statistically different, while such values for the other two autografts were significantly less. The strength values of all three autografts were significantly less than those of the scapholunate interosseous ligament. This study indicates that of the potential autografts tested, the tarsometatarsal ligament is biomechanically most similar to the intact scapholunate interosseous ligament.
进行了一项尸体研究,以确定一种可用于修复舟月骨间韧带断裂的潜在自体移植物。选择了三个韧带复合体(第四和第五跖骨的背侧跖骨韧带、一个背侧跗跖韧带和跟骰背侧韧带)作为自体移植物候选。从六具新鲜冷冻男性尸体(年龄51 - 68岁)匹配的手和足中获取舟月骨间韧带和三个自体移植物候选作为骨-韧带-骨复合体。使用伺服液压试验机以0.1 mm/s的恒定夹距速率拉伸这些复合体,直至失效。计算并比较每个韧带复合体的刚度和强度值。分析表明,跗跖韧带和舟月骨间韧带的刚度值在统计学上无差异,而其他两种自体移植物的刚度值明显较低。所有三种自体移植物的强度值均明显低于舟月骨间韧带。这项研究表明,在所测试的潜在自体移植物中,跗跖韧带在生物力学上与完整的舟月骨间韧带最为相似。