Suppr超能文献

采用电解电导和电子捕获检测的气相色谱法测定脱咖啡因速溶咖啡和研磨咖啡中的残留二氯甲烷和三氯乙烯。

Gas chromatographic determination of residual methylene chloride and trichloroethylene in decaffeinated instant and ground coffee with electrolytic conductivity and electron capture detection.

作者信息

Page B D, Charbonneau C F

出版信息

J Assoc Off Anal Chem. 1977 May;60(3):710-5.

PMID:858707
Abstract

A method is described for the quantitative determination of residual methylene chloride (MC) and trichloroethylene (TCE) in decaffeinated instant and ground roasted coffees. The residual solvents were isolated by a closed system vacuum distillation technique with toluene as a carrier solvent, chromatographed on Chromosorb 102, detected by both electron capture and electrolytic conductivity detectors, and quantitated by comparison with an internal standard. Average recoveries of MC from instant and ground coffees spiked at 1, 10, and 25 ppm were 100.0 (88-113), 93.2 (92-95), and 97.7% (94-102%); and for TCE, 97.2 (92-101), 96.2 (95-99), and 96.5% (92-100%), respectively. The results from both detectors are compared. At lower attenuations, levels less than 1 ppm can be readily measured. The procedure developed was applied to domestic and imported coffee samples.

摘要

描述了一种定量测定脱咖啡因速溶咖啡和烘焙咖啡中残留二氯甲烷(MC)和三氯乙烯(TCE)的方法。残留溶剂通过以甲苯为载体溶剂的封闭系统真空蒸馏技术进行分离,在Chromosorb 102上进行色谱分析,通过电子捕获检测器和电解电导检测器进行检测,并与内标物比较进行定量。在速溶咖啡和烘焙咖啡中分别加入1、10和25 ppm的MC,平均回收率分别为100.0(88 - 113)、93.2(92 - 95)和97.7%(94 - 102%);对于TCE,平均回收率分别为97.2(92 - 101)、96.2(95 - 99)和96.5%(92 - 100%)。比较了两种检测器的结果。在较低衰减下,可以轻松测量低于1 ppm的含量。所开发的方法应用于国产和进口咖啡样品。