• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Case study: control of methylene chloride exposures during furniture stripping.

作者信息

Estill C F, Spencer A B

机构信息

U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, Cincinnati, Ohio 45226, USA.

出版信息

Am Ind Hyg Assoc J. 1996 Jan;57(1):43-9. doi: 10.1080/15428119691015205.

DOI:10.1080/15428119691015205
PMID:8588552
Abstract

Methylene chloride, a potential occupational carcinogen, is one of the principal solvents used for furniture stripping. Methylene chloride exposures among workers in furniture stripping operations have been found to be high. This article describes a furniture stripping operation at a sheltered workshop before and after the ventilation system was modified. Previous to ventilation system modifications, workers who were stripping furniture had exposures to methylene chloride ranging from 600 to 1150 ppm. These high exposures and an evaluation of the ventilation system prompted the design and installation of a modified ventilation system. Primary modifications included installing a local ventilation hood, decreasing the velocity of makeup air entering the stripping area, removing a contaminated charcoal adsorption bed and improving work practices. The modified system was arranged into three configurations that included a slot hood, a downdraft hood, and a combination slot and downdraft hood. The three configurations were evaluated over a three-day period, and it was found that they controlled the worker's personal exposures to methylene chloride while stripping to 28 ppm for the combination configuration, 30 ppm for the downdraft configuration, and 34 ppm for the slot configuration. Although the exposures are above the proposed Occupational Safety and Health Administration permissible exposure level of 25 ppm, these results show a substantial improvement over the existing ventilation system. The ventilation system described is applicable to other furniture stripping facilities if rinse area local ventilation is improved.

摘要

相似文献

1
Case study: control of methylene chloride exposures during furniture stripping.
Am Ind Hyg Assoc J. 1996 Jan;57(1):43-9. doi: 10.1080/15428119691015205.
2
Overexposure and control of methylene chloride in a furniture stripping operation.
J Occup Environ Hyg. 2007 May;4(5):D39-41. doi: 10.1080/15459620701246372.
3
Engineering controls for furniture strippers to meet the OSHA methylene chloride PEL.
AIHA J (Fairfax, Va). 2002 May-Jun;63(3):326-33. doi: 10.1080/15428110208984721.
4
The impact of maintenance and design for ventilation systems.
Appl Occup Environ Hyg. 2002 May;17(5):344-51. doi: 10.1080/10473220252864941.
5
Fatal exposure to methylene chloride among bathtub refinishers - United States, 2000-2011.浴缸翻新工人接触二氯甲烷致 2000-2011 年美国致死病例。
MMWR Morb Mortal Wkly Rep. 2012 Feb 24;61(7):119-22.
6
Furniture strippers need to adopt a pollution prevention approach.
AIHA J (Fairfax, Va). 2002 Nov-Dec;63(6):676; author reply 676-7.
7
Exposure assessment of organic solvents for aircraft paint stripping and spraying workers.飞机喷漆剥离和喷涂工人有机溶剂暴露评估
Sci Total Environ. 2006 Mar 1;356(1-3):38-44. doi: 10.1016/j.scitotenv.2005.02.029.
8
Methylene chloride exposure in furniture-stripping shops: ventilation and respirator use practices.
J Occup Med. 1990 Jan;32(1):33-7. doi: 10.1097/00043764-199001000-00010.
9
Hard metal exposures. Part 1: Observed performance of three local exhaust ventilation systems.硬质合金暴露。第1部分:三种局部排风通风系统的实际运行情况。
Appl Occup Environ Hyg. 2000 Apr;15(4):331-41. doi: 10.1080/104732200301458.
10
An evaluation of a local exhaust ventilation control system for a foundry casting-cleaning operation.对铸造厂铸件清理作业局部排风通风控制系统的评估。
Am Ind Hyg Assoc J. 1997 May;58(5):354-8. doi: 10.1080/15428119791012711.