Suppr超能文献

视频验光:模糊圈直径与屈光不正之间的关系。

Video-photorefraction: the relationship between blur circle diameter and refractive error.

作者信息

Jennings D S, Jennings J A

机构信息

School of Optometry, University of Waterloo, Ontario, Canada.

出版信息

Ophthalmic Physiol Opt. 1995 Nov;15(6):605-7.

PMID:8594532
Abstract

When using a videorefractor (VPR-1) the margins of the defocused blur circles are sometimes poorly defined and difficult to locate. To investigate the effect this may have on the apparent refractive error, the relationship between blur circle diameter and refractive error was found by videoing circles of known size and inputting these data as pupil and blur circle diameters. The results indicate that for accuracy of 0.50 D blur circles need to be defined to approximately equal to 1 mm.

摘要

使用视频验光仪(VPR - 1)时,散焦模糊圈的边缘有时界定不清且难以定位。为研究这可能对表观屈光不正产生的影响,通过拍摄已知大小的圆圈并将这些数据作为瞳孔和模糊圈直径输入,得出了模糊圈直径与屈光不正之间的关系。结果表明,为达到0.50 D的精度,模糊圈需界定为约等于1毫米。