Suppr超能文献

夹子对牙刷刷毛磨损的影响。

Effect of a clamp on toothbrush bristle deterioration.

作者信息

Schneider P, Musselman R, Sarkar N K

机构信息

Department of Pediatric Dentistry, Louisiana State University School of Dentistry, New Orleans, USA.

出版信息

J Clin Dent. 1995;6(4):198-201.

PMID:8624232
Abstract

The purpose of this study was to evaluate, in vitro, the effectiveness of a device to prevent toothbrush deterioration. Ten toothbrushes from each of four brands, Oral-B 40, Py-co-pay Softex 12.0 row, Butler #330, and Oral-B 20, were divided into control and experimental groups. Toothbrushes were fixed into a machine that simulated toothbrushing by producing a reciprocating motion 41.5 mm in length at a rate of 380 strokes/min. Bristles slid over a ceramic disc that had a hardness similar to dental enamel. Pressure (450 g) was applied at a right angle to the toothbrush while it moved back and forth in a slurry of toothpaste. The pressure was calibrated with load cells. Toothbrushes were run for 15 minutes followed by a drying cycle for a total of four hours, or approximately equivalent to brushing twice daily for six months. During the drying cycle the bristles of the toothbrushes in the experimental group were compressed 3/4 their length from the brush head with a clamp (Gregory Patent #4884311). Bristle deterioration was evaluated based on Wear Index (WI), a quantitative means of ranking brushes in various stages of deterioration. Data on WI and WR showed that toothbrushes in the experimental group had significantly (< or = 0.005) less deterioration. Improvement in wear resistance was dependent on size and configuration of the bristles. Compressing the bristles between brushings retains the non-matted shape of the bristles and reduces their deterioration.

摘要

本研究的目的是在体外评估一种防止牙刷损坏的装置的有效性。从四个品牌(欧乐-B 40、Py-co-pay Softex 12.0排、巴特勒#330和欧乐-B 20)中各选取10支牙刷,分为对照组和实验组。将牙刷固定在一台机器上,该机器通过以380次/分钟的速度产生41.5毫米长的往复运动来模拟刷牙。刷毛在一块硬度与牙釉质相似的陶瓷盘上滑动。当牙刷在牙膏浆中来回移动时,以直角施加450克的压力。压力用称重传感器校准。牙刷运行15分钟,随后进行干燥循环,总共4小时,大约相当于每天刷牙两次,持续6个月。在干燥循环期间,用夹具将实验组牙刷的刷毛从刷头处压缩至其长度的3/4(格雷戈里专利#4884311)。基于磨损指数(WI)评估刷毛损坏情况,WI是一种对处于不同损坏阶段的牙刷进行排名的定量方法。关于WI和WR的数据表明,实验组的牙刷损坏明显更少(≤0.005)。耐磨性的提高取决于刷毛的尺寸和形状。在刷牙之间压缩刷毛可保持刷毛的非缠结形状并减少其损坏。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验