Analysis of localization errors in the definition of the mantle field using a beam's eye view treatment-planning system.

作者信息

Naida J D, Eisbruch A, Schoeppel S L, Sandler H M, Turrisi A T, Lichter A S

机构信息

Department of Radiation Oncology, University of Michigan Medical Center, Ann Arbor 48109, USA.

出版信息

Int J Radiat Oncol Biol Phys. 1996 May 1;35(2):377-82. doi: 10.1016/0360-3016(96)00085-5.

DOI:10.1016/0360-3016(96)00085-5
PMID:8635947
Abstract

PURPOSE

Reports of the treatment of Hodgkin's disease (HD) with radiotherapy using the mantle field technique have demonstrated that coverage of disease by the field blocks significantly compromises outcome. It is our hypothesis that the availability of computerized tomography images reduces the incidence of localization error, and that the use of beam's eye view treatment planning techniques may further improve localization. The purpose of this report is to assess the possible contribution of a three-dimensional treatment-planning system to tumor localization and mantle block drawing in patients with HD.

MATERIALS AND METHODS

We evaluated the localization error rate of four experienced radiation oncologists as they drew the lung blocks for the mantle field. The analysis included 16 patients treated with mantle fields in our department between 1989 and 1991. In each case our computerized three-dimensional treatment planning system was used to generate a beam's eye view display of tumor volumes. Simulation radiographs for all 16 patients were overlaid with acetate film, and lung blocks were drawn by clinicians using only the simulation radiographs for reference. The process was repeated with the thoracic CT scans available for reference. The mantle block contours for each trial were then superimposed upon the beam's eye view plots of tumor volumes. The beam's eye view plot was our benchmark for the evaluation of errors of tumor localization. Localization errors were defined as touching or overlap of the shielding blocks onto tumors.

RESULTS

There was a high degree (p < 0.0003) of consistency in scoring across all pairing of clinicians and the results from all four were polled for the analysis. The overall error rate using the simulation radiographs alone was 18%. The rate was significantly lower (13%) when the CT images were available (p = 0.038). The axillary region had the highest localization error rate (41.7% with CT available and 27.1% with CT available) and the superior mediastinum had the lowest error rate (10.7% without CT, 8.5% with CT). Compared with a system such as beam's eye view, which could reduce the localization error rate to zero, the error rate with CT scans available is still significant [95% confidence interval (CI = 10-17.1%)]. Localization errors were more likely with increasing tumor size when CT scans were not available (p = 0.029). A similar trend was not seen when CT scans were available (p = 0.2). In a multivariate analysis, the use of CT scans predicted for reduced localization error rate (p = 0.03). Tumors in the axilla and inferior mediastinum had a greater relative risk than those in the superior mediastinum (p = 0.0001)

CONCLUSION

The availability of CT imaging offers an advantage in the outlining of the mantle field in the treatment of Hodgkin's disease. When the error rate is evaluated using a beam's eye view treatment planning system, a significant proportion of tumors may be overlapped by the outlined mantle blocks even when CT images are available for reference. The use of beam's eye view treatment planning in mantle field definition, especially for tumors in the axillary region, may reduce the incidence of geographic misses.

摘要

相似文献

1
Analysis of localization errors in the definition of the mantle field using a beam's eye view treatment-planning system.
Int J Radiat Oncol Biol Phys. 1996 May 1;35(2):377-82. doi: 10.1016/0360-3016(96)00085-5.
2
An alternative mantle irradiation technique using 3D CT- based treatment planning for female patients with Hodgkin's disease.一种针对女性霍奇金病患者的、使用基于三维CT治疗计划的替代性斗篷野照射技术。
Int J Radiat Oncol Biol Phys. 2000 Jun 1;47(3):739-48. doi: 10.1016/s0360-3016(00)00438-7.
3
Beam's eye view based prostate treatment planning: is it useful?
Int J Radiat Oncol Biol Phys. 1990 Sep;19(3):759-68. doi: 10.1016/0360-3016(90)90507-g.
4
Comparison of conventional and virtual simulation for radiation treatment planning of malignant lymphoma.恶性淋巴瘤放射治疗计划的传统模拟与虚拟模拟比较
Strahlenther Onkol. 1998 Oct;174 Suppl 2:28-30.
5
Full integration of the beam's eye view concept into computerized treatment planning.将射野视角概念全面整合到计算机化治疗计划中。
Int J Radiat Oncol Biol Phys. 1990 Jun;18(6):1485-94. doi: 10.1016/0360-3016(90)90325-e.
6
Differences in target outline delineation from CT scans of brain tumours using different methods and different observers.使用不同方法和不同观察者对脑肿瘤CT扫描进行靶区轮廓勾画的差异。
Radiother Oncol. 1999 Feb;50(2):151-6. doi: 10.1016/s0167-8140(99)00015-8.
7
Implementation of Beam's Eye View into routine treatment planning and delivery.
Med Dosim. 1990;15(3):147-50. doi: 10.1016/0958-3947(90)90055-m.
8
Beam's eye view--based radiation therapy: description of methods.
Radiographics. 1992 Sep;12(5):961-8. doi: 10.1148/radiographics.12.5.1529136.
9
Potential clinical efficacy of intensity-modulated conformal therapy.调强适形放疗的潜在临床疗效。
Int J Radiat Oncol Biol Phys. 1998 Jan 15;40(2):483-95. doi: 10.1016/s0360-3016(97)00819-5.
10
Beam's eye view volumetrics: an aid in rapid treatment plan development and evaluation.射野视角容积测量法:有助于快速制定和评估治疗计划
Int J Radiat Oncol Biol Phys. 1992;23(2):367-75. doi: 10.1016/0360-3016(92)90755-7.