减少超声骨刀产生的气溶胶。

Reduction of aerosols produced by ultrasonic scalers.

作者信息

Harrel S K, Barnes J B, Rivera-Hidalgo F

机构信息

Department of Periodontology, Baylor College of Dentistry, Dallas, TX, USA.

出版信息

J Periodontol. 1996 Jan;67(1):28-32. doi: 10.1902/jop.1996.67.1.28.

Abstract

There is concern with decreased air quality and potential aerosol contamination in the dental operatory. This problem has been addressed by the Centers for Disease Control and Prevention, which recommends that all sources of blood-contaminated splatter and aerosols be minimized. One of the major sources of potential aerosol contamination in the dental setting is the ultrasonic scaler. This study looks at the use of a high volume evacuator attachment for the ultrasonic scaler handpiece. Artificial teeth were mock-scaled for 1 minute with and without the evacuator attachment. The mock scaling was performed within a plastic enclosure that had a 1 cm grid laid out on 4 sides. Scaling was performed 10 times each by 2 operators. An erythrosin solution was used for the ultrasonic scaler coolant with a coolant volume of 17.5 ml/min. The number of squares containing a red erythrosin spot were counted and considered to represent aerosol contamination. The high volume evacuator attachment produced a 93% reduction in the number of contaminated squares (chi squared significant at P < 0.05). There was no increase in heat transfer to a tooth analogue when the high volume evacuator attachment was used with the ultrasonic scaler as compared to the scaler without the evacuator attachment. It is felt that the high volume evacuator attachment is capable of significantly reducing the amount of aerosol contamination produced within the test system without increased heat transfer to the tooth.

摘要

人们担心牙科治疗室的空气质量下降和潜在的气溶胶污染。疾病控制与预防中心已解决了这个问题,该中心建议尽量减少所有血液污染飞溅物和气溶胶的来源。牙科环境中潜在气溶胶污染的主要来源之一是超声波洁牙器。本研究观察了一种用于超声波洁牙器机头的大容量抽吸附件的使用情况。在有和没有抽吸附件的情况下,对人工牙齿进行了1分钟的模拟洁牙。模拟洁牙在一个塑料罩内进行,该塑料罩的四周设有1厘米的网格。两名操作人员各进行了10次洁牙操作。将赤藓红溶液用作超声波洁牙器的冷却液,冷却液流量为17.5毫升/分钟。对含有红色赤藓红斑点的方格数量进行计数,并将其视为代表气溶胶污染。大容量抽吸附件使污染方格的数量减少了93%(卡方检验在P < 0.05时具有显著性)。与没有抽吸附件的洁牙器相比,当大容量抽吸附件与超声波洁牙器一起使用时,传递到牙齿模拟物上的热量没有增加。据认为,大容量抽吸附件能够显著减少测试系统内产生的气溶胶污染量,同时不会增加传递到牙齿上的热量。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验