Schmitz-Rode T, Alzen G, Spetzger U, Günther R W
Klinik für Radiologische Diagnostik, Klinikum der RWTH Aachen.
Rofo. 1996 Feb;164(2):150-2. doi: 10.1055/s-2007-1015628.
A 58-year-old patient with extensive pulmonary embolism complicated by cardiogenic shock and contraindications to thrombolysis was treated by mechanical embolus fragmentation using a rotatable pigtail catheter system. Considerable recanalization of the left pulmonary arteries was rapidly achieved with relative ease of instrumentation. Subsequently, the hemodynamic condition stabilized.
一名58岁的广泛肺栓塞患者,合并心源性休克且有溶栓禁忌证,采用可旋转猪尾导管系统进行机械性栓子破碎治疗。相对轻松地操作迅速实现了左肺动脉的显著再通。随后,血流动力学状况稳定。